Measurement of the migration of a focal knee resurfacing implant with radiostereometry

نویسندگان

  • Olof Sköldenberg
  • Thomas Eisler
  • André Stark
  • Olle Muren
  • Nicolas Martinez-Carranza
  • Leif Ryd
چکیده

BACKGROUND AND PURPOSE Articular resurfacing metal implants have been developed to treat full-thickness localized articular cartilage defects. Evaluation of the fixation of these devices is mandatory. Standard radiostereometry (RSA) is a validated method for evaluation of prosthetic migration, but it requires that tantalum beads are inserted into the implant. For technical reasons, this is not possible for focal articular resurfacing components. In this study, we therefore modified the tip of an articular knee implant and used it as a marker for RSA, and then validated the method. MATERIAL AND METHODS We modified the tip of a resurfacing component into a hemisphere with a radius of 3 mm, marked it with a 1.0-mm tantalum marker, and implanted it into a sawbone marked with 6 tantalum beads. Point-motion RSA of the "hemisphere bead" using standard automated RSA as the gold standard was compared to manual measurement of the tip hemisphere. 20 repeated stereograms with gradual shifts of position of the specimen between each double exposure were used for the analysis. The tip motion was compared to the point motion of the hemisphere bead to determine the accuracy and precision. RESULTS The accuracy of the manual tip hemisphere method was 0.08-0.19 mm and the precision ranged from 0.12 mm to 0.33 mm. INTERPRETATION The accuracy and precision for translations is acceptable when using a small hemisphere at the tip of a focal articular knee resurfacing implant instead of tantalum marker beads. Rotations of the implant cannot be evaluated. The method is accurate and precise enough to allow detection of relevant migration, and it will be used for future clinical trials with the new implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of migration of a humeral head resurfacing prosthesis using radiostereometry without implant marking

INTRODUCTION Standard radiostereometric analysis of prosthetic migration requires that tantalum beads are inserted into the implant. For manufacturing reasons, this is not possible for humeral head resurfacing implants. We therefore used marker-free radiostereometry, developed for metal-backed acetabular cups, on a dummy model to validate the method for a humeral head resurfacing prosthesis. ...

متن کامل

Comparison of Clinical Results between Patellar Resurfacing and Non-resurfacing in Total Knee Arthroplasty: A Short Term Evaluation

Background: There is no difference in the functional outcomes 6 months after total knee arthroplasty (TKA) for kneeosteoarthritis between patellar resurfacing and non-resurfacing. Thus, we have performed this study to compare theshort-term clinical outcomes of TKA performed with and without the patella resurfacing.Methods: A total of 50 patients with osteoarthritis of the knee (OAK) were random...

متن کامل

Comparison between Patellar Resurfacing and Retention in Total Knee Arthroplasty Regarding the Postoperative Satisfaction of Patients and Patellar Crepitus

Background: Patellar crepitus after total knee arthroplasty (TKA) is not uncommon. The choice between patellarresurfacing or retention in TKA has remained controversial. Therefore, this randomized controlled trial aimed to evaluatethe impact of patellar resurfacing on the incidence of patellar crepitus. In addition, we compared the clinical outcomesand satisfaction between the...

متن کامل

COMPARING THE SATISFACTION RATE IN PATIENTS WITH TOTAL KNEE ARTHROPLASTY (TKA) SURGERY IN TWO GROUPS OF WITH AND WITHOUT PATELLA RESURFACING

This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran

متن کامل

Once-weekly oral medication with alendronate does not prevent migration of knee prostheses

BACKGROUND AND PURPOSE Early migration of joint replacements is an effect of poor fixation and can predict late loosening. By reducing the bone resorption after implantation of a joint replacement, it should be possible to enhance the initial fixation of the implant. We studied the effect of once-weekly treatment with alendronate after knee replacement. PATIENTS AND METHODS We recruited 60 pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 85  شماره 

صفحات  -

تاریخ انتشار 2014