Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database Application Note

نویسندگان

  • Bruce Quimby
  • Mike Szelewski
چکیده

Response to homeland security or environmental incidents involving hazardous chemicals requires first, the rapid and accurate identification of the chemical agent(s) involved and second, the quantitative measurement of that agent in large numbers of samples to aid in managing the response. Given the unknown nature of the analytes and the complexity of matrices that could be encountered, developing analytical methods for this analysis is challenging. The approach described in this work uses a gas chromatography/mass spectrometry (GC/MS) system with a micro-fluidic splitter added to the end of the column. The splitter divides the column effluent between the MS and either a dual-wavelength flame photometric detector (DFPD) or a micro electron-capture detector (μECD) and a single-wavelength FPD. This approach allows the simultaneous collection of MS and two channels of selective GC detector data from a single injection. This multisignal configuration provides: full-scan MS data for library searching, selective ion monitoring (SIM) data for trace analysis, μECD and FPD data for excellent selectivity and sensitivity in complex matrices. The systems use retention time locking (RTL) to produce retention times (RTs) that precisely match those in a 731 compound database of hazardous chemicals. Deconvolution Reporting Software (DRS) is used to provide fast and accurate Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Screening for 171 Volatile Organic Air Pollutants Using GC/MS with Deconvolution Reporting Software and a New Indoor Air Toxics Library Application

A retention-time-locked mass spectral database was created specifically for indoor air analysis by thermal desorption/gas chromatography/mass spectroscopy (TD/GC/MS). This Indoor Air Toxics Database contains locked retention times and mass spectra for 171 volatile and semivolatile organic compounds that are targets in various indoor air methods. In combination with Agilent's Deconvolution Repor...

متن کامل

Screening for Pesticides in Food Using the Japanese Positive List Pesticide Method: Benefits of Using GC/MS with Deconvolution Reporting Software and a Retention Time Locked Mass Spectral Database Application

In 2006, the Japanese Ministry of Health, Labour and Welfare introduced a new system for the regulation of pesticides, feed additives, and veterinary drugs. This “Positive List” system stipulates that only compounds on the approved list can be used in food production and provides the framework for regulation of these compounds. These new regulations have increased the need for analytical method...

متن کامل

Improved Forensic Toxicology Screening Using A GC/MS/NPD System with a 725-Compound DRS Database Application

Laboratories that perform toxicology screens are challenged by the requirement to look for large numbers of target compounds in samples that contain complex matrix interferences. GC/MS methods are widely used and accepted for this analysis. Full-scan EI methods offer many advantages for broad-range screening, such as unlimited numbers of targets, full-spectrum identity confirmation, and library...

متن کامل

Field Evaluation of Screening Techniques for Polycyclic Aromatic Hydrocarbons, 2,4-Diphenoxyacetic Acid, and Pentachlorophenol in Air, House Dust, Soil, And Total Diet

The objectives of this work assignment were to evaluate ELISA screening methods and determine whether these methods indicate effectively those microenvironments where high exposure to polycyclic aromatic hydrocarbons (PAH) or other semivolatile organic compounds (SVOC) is likely. Four commercially available assay kits for PAH, carcinogenic PAH (C-PAH), 2,4-D, and pentachlorophenol (PCP) were ev...

متن کامل

Screening and Identification of Emerging Contaminants in Wastewater Treatment Plant Effluents Using UHPLC/Q-TOF MS and an Accurate Mass Database and Library

This application note describes the creation of an accurate mass library for relevant environmental contaminants and its application for the screening of pesticides, pharmaceuticals and personal care products, their metabolites, and transformation products in effluents of municipal waste water treatment plants (WWTPs). An Agilent 1290 Infinity LC System coupled to an Agilent 6550 iFunnel Q-TOF ...