MADOR: a new tool to calculate decrease of effective doses in human after DTPA therapy.

نویسندگان

  • P Fritsch
  • O Grémy
  • C Hurtgen
  • P Bérard
  • L Grappin
  • J L Poncy
چکیده

Abstract models have been developed to describe dissolution of Pu/Am/Cm after internal contamination by inhalation or wound, chelation of actinides by diethylene triamine penta acetic acid (DTPA) in different retention compartments and excretion of actinide-DTPA complexes. After coupling these models with those currently used for dose calculation, the modelling approach was assessed by fitting human data available in IDEAS database. Good fits were obtained for most studied cases, but further experimental studies are needed to validate some modelling hypotheses as well as the range of parameter values. From these first results, radioprotection tools are being developed: MAnagement of DOse Reduction after DTPA therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimating the Absorbed Dose of Organs in Pediatric Imaging of 99mTc-DTPA Radiopharmaceutical using MIRDOSE Software

Introduction: In this study, organ radiation doses were calculated for the renal agent 99mTc-DTPA in children. Bio-kinetic energy of 99mTc-DTPA was evaluated by scintigraphy and estimates for absorbed radiation dose were provided using standard medical internal radiation dosimetry (MIRD) techniques.Material and Methods: In this applied research, fourteen children patients (6 males and 8 females...

متن کامل

Introduction of new derivatives of Biotin and DTPA for labeling of antibodies with ¹¹¹In to detect malignant tumors [Persian]

Radiolabeled monoclonal antibodies, have created new innovations in diagnosis, research and therapy of disease in last 2 decades. One of the serious limitation of applications of radiolabeled antibodies in vivo is relatively low target to background activity. Various strategies have been proposed to solve this problem including pre-targeting methods that was suggested in 1989. Regarding i...

متن کامل

Determination of organ doses in radioiodine therapy using medical internal radiation dosimetry (MIRD) method

Background: Radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. The scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (MIRD) method. At the end, the results of MIRD calculations were compared with thermoluminescent dosimeter (TLD...

متن کامل

Assessment of patients’ entrance skin and effective dose in a mathematical human phantom for the most common interventional radiological examinations

Introduction: Nowadays, we are witnessing an exponential use of interventional radiology techniques in different communities. After CT, interventional techniques are the second factor of increasing patients’ doses in different societies. Measuring patient doses from aforementioned methods has been recommended by many radiation protection professional organizations such as ICRP...

متن کامل

Synthesis, labeling and quality control of a new Neuropeptide Y analogue for diagnosis of breast tumors

  Introduction: Over expression of selected peptide receptors in human tumors has been shown to represent clinically relevant targets for cancer diagnosis and therapy. The aim of this work was to investigate Neuropeptide Y (NPY) as a new radiopharmaceutical for diagnosis of breast cancer. Methods: A neuropeptide Y analogues with Y1 receptor preference and agonistic p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 144 1-4  شماره 

صفحات  -

تاریخ انتشار 2011