In Vivo Dosimetry of an Anthropomorphic Phantom Using the RADPOS for Proton Beam Therapy

نویسندگان

  • Ryosuke Kohno
  • Hidenori Yamaguchi
  • Kana Motegi
  • Kenji Hotta
  • Shie Nishioka
  • Tetsuo Akimoto
چکیده

The radiation positioning system (RADPOS) combines an electromagnetic positioning sensor with metal oxide semiconductor field-effect transistor (MOSFET) dosimetry, enabling simultaneous online measurement of dose and spatial position. Evaluation points can be determined with the RADPOS. The accuracy of in-vivo proton dosimetry was evaluated using the RADPOS and an anthropomorphic head and neck phantom. MOSFET doses measured at 3D positions obtained with the RADPOS were compared with treatment plan values calculated using a simplified Monte Carlo (SMC) method. MOSFET responses, which depend strongly on the linear energy transfer of the proton beam, were corrected using the SMC method. The SMC method was used to calculate only dose deposition determined by the experimental depth-dose distribution and lateral displacement of protons due to the multiple scattering effect in materials and incident angle. This method thus enabled rapid calculation of accurate doses in even heterogeneities. In vivo dosimetry using the RADPOS, as well as MOSFET doses, agreed with SMC calculations in the range of −3.0% to 8.3%. Most measurement errors occurred because of uncertainties in dose calculations due to the 1-mm position error. The results indicate that uncertainties in measurement position can be controlled successfully within 1 mm when using the RADPOS with in-vivo proton dosimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Position Verification of the RADPOS 4-D In-Vivo Dosimetry System

The accuracy of the position measurements obtained by the radiation positioning system (RADPOS) was evaluated under static and dynamic conditions. In the static verifications, the RADPOS was fixed to the treatment couch in a photon treatment room and a proton treatment room, and was translocated with the treatment couch in x, y and z directions. Because the presence of magnetic and/or electrica...

متن کامل

Assessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

متن کامل

Effects of Defining Realistic Compositions of the Ocular Melanoma on Proton Therapy

Background: Recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. In spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. In the presented work, the effect of utilizing an eye model with ocular media on pr...

متن کامل

Monte Carlo calculations of dose distribution for the treatment of gastric cancer with proton therapy

Proton therapy is a common form of external radiation therapy based on the manipulation of Bragg peak of this beam, it can treat the tumor by delivering high levels of doses to it, while protecting surrounding healthy tissues against radiation. In this work, the dose distribution of proton and secondary particles such as neutrons, photons, electrons and positrons in gastric cancer proton therap...

متن کامل

Proton Therapy of eye using MCNPX code

Introduction: Proton radiotherapy is the one of advanced teletherapy methods. The protons deposit their maximum energy in a position called Bragg peak. Therefore, for treatment of cancer, the tumor should be placed at the Bragg peak or SOBP. The scattered photons and neutrons is a challenge in proton radiotherapy. The aim of this study is calculation of absorbed dose from scatt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016