Patient radiation dose management in the follow-up of potential skin injuries in neuroradiology.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Radiation exposure from neurointerventional procedures can be substantial, with risk of radiation injuries. We present the results of a follow-up program applied to potential skin injuries in interventional neuroradiology based on North American and European guidelines. MATERIALS AND METHODS The following guidelines approved in 2009 by SIR and CIRSE have been used over the last 2 years to identify patients with potential skin injuries requiring clinical follow-up: peak skin dose >3 Gy, air kerma at the patient entrance reference point >5 Gy, kerma area product >500 Gy · cm(2), or fluoroscopy time >60 minutes. RESULTS A total of 708 procedures (325 in 2009 and 383 in 2010) were included in the study. After analyzing each dose report, 19 patients (5.9%) were included in a follow-up program for potential skin injuries in 2009, while in 2010, after introducing several optimizing actions and refining the selection criteria, only 4 patients (1.0%) needed follow-up. Over the last 2 years, only 3 patients required referral to a dermatology service. CONCLUSIONS The application of the guidelines to patient radiation dose management helped standardize the selection criteria for including patients in the clinical follow-up program of potential skin radiation injuries. The peak skin dose resulted in the most relevant parameter. The refinement of selection criteria and the introduction of a low-dose protocol in the x-ray system, combined with a training program focused on radiation protection, reduced the number of patients requiring clinical follow-up.
منابع مشابه
PATIENT SAFETY Patient Radiation DoseManagement in the Follow-Up of Potential Skin Injuries in Neuroradiology
BACKGROUND AND PURPOSE: Radiation exposure from neurointerventional procedures can be substantial, with risk of radiation injuries. We present the results of a follow-up program applied to potential skin injuries in interventional neuroradiology based on North American and European guidelines. MATERIALS ANDMETHODS: The following guidelines approved in 2009 by SIR and CIRSE have been used over t...
متن کاملSubcutaneous Extravasation of Sr-89: Usefulness of Bremsstrahlung Imaging in Confirming Sr-89 Extravasation and in the Decision Making for the Choice of Treatment Strategies for Local Radiation Injuries Caused by Sr-89 Extravasation
A male patient in his 20s presented at our clinic with pain caused by bone metastases of the primitive neuroectodermal tumor, and Sr-89 was administrated to palliate the pain. After receiving the injection, the patient complained of a slight burning pain at the catheterized area. Slight reddening and small circular swelling (diameter, 0.5 cm) were observed at the catheterized area. Sr-89 extrav...
متن کاملAssessment of Patient Dose with Special Look at Pediatrics during Cardiovascular Imaging
Background: During interventional cardiology processes, patients especially women and children receive high radiation doses due to their sensitivity.Objective: In this study, we evaluated a pediatric patient dose separately in those undergone intervention cardiac procedure. Material and Methods: In this cross sectional study, a public hospital with 252 patients, Entrance Skin Dose (...
متن کاملPatient dose values during interventional cardiology examinations in Yazd hospital, Iran
Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...
متن کاملA dosimetric study of deep skin electron therapy with overlapping stationary radiation fields – A case report
Background: For radiotherapy of total skin including sub-cutaneous tissue up to a depth of 3 cm on the entire left leg of an adult (Angiosarcoma skin), a complex treatment with multiple stationary electron fields was planned at our clinic. The details of dosimetry, clinical dose measurements are presented. Materials and Methods: The treatment planned with 6 overlapping 9 MeV electron fields in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 34 2 شماره
صفحات -
تاریخ انتشار 2013