Characterization of an Ellipsoidal Radiometer

نویسندگان

  • Annageri V. Murthy
  • Ingrid Wetterlund
  • David P. DeWitt
چکیده

An ellipsoidal radiometer has been characterized using a 25 mm variable-temperature blackbody as a radiant source. This radiometer is intended for separating radiation from convection effects in fire test methods. The characterization included angular response, responsivity, and purge-gas flow effect studies. The angular response measurements showed that the reflection from the radiometer cavity was higher on one of the cavity halves relative to the other half. Further development work may be necessary to improve the angular response. The responsivity measured with reference to a transfer-standard electrical-substitution radiometer showed dependence on the distance of the radiometer from the blackbody cavity. The purge-gas had the effect of reducing the signal output nearly linearly with flow rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Description of a myxozoan parasite Myxobolus sp.n PKB2014 from an edible fish, with emphasis on its molecular characterization

In India, more than 104 species of Myxobolus have so far been reported infecting freshwater as well as marine fishes. The study focuses on the description of a new myxosporean species, Myxobolus sp.n PKB 2014 from the gill lamellae of an Indian major carp Labeo rohita. The species have been described on the basis of morphological characterization of the spores, tissue architecture and 18S rDNA ...

متن کامل

PBPL Publications: 2008-00014 PUBLICATION EXPERIMENTAL GENERATION AND CHARACTERIZATION OF UNIFORMLY FILLED ELLIPSOIDAL BEAM DISTRIBUTION

Recently, a scheme for producing ideal uniformly filled ellipsoidal beam distributions, which depends on the strong longitudinal expansion of an initially very short beam under its own space charge forces, has been demonstrated at the UCLA Pegasus Laboratory. Here we present further work on the characterization of this novel regime of operation of a photoinjector. In particular we study the sen...

متن کامل

Producing Gravity Acceleration at Sea Surface in Persian Gulf Using Ellipsoidal Splines

In this paper, a method is proposed for producing gravity acceleration at sea surface in the Persian Gulf. This method is based on the Geoid height from satellite altimetry, high resolution Geopotential models, and ellipsoidal splines. First, the definition of the ellipsoidal spline functions is presented in a Hilbert space, which is consisted of infinitely often differentiable functions. In or...

متن کامل

High-power and high-accuracy integrating sphere radiometer: design, characterization, and calibration.

We describe the design, characterization, and calibration of a high-power and high-accuracy transfer standard for optical power measurements in fibers based on an integrating sphere radiometer working from -50 to +30 dBm. The integrating sphere radiometer has been calibrated in the spectral range 1250-1650 nm by use of an electrically calibrated pyroelectric radiometer and four tunable laser di...

متن کامل

Experimental Generation and Characterization of Uniformly Filled Ellipsoidal Beam Distribution

Recently, a scheme for producing ideal uniformly filled ellipsoidal beam distributions, which depends on the strong longitudinal expansion of an initially very short beam under its own space charge forces, has been demonstrated at the UCLA Pegasus Laboratory. Here we present further work on the characterization of this novel regime of operation of a photoinjector. In particular we study the sen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 108  شماره 

صفحات  -

تاریخ انتشار 2003