Liquid chromatography of codeine in plasma with fluorescence detection.
نویسندگان
چکیده
This analytical method for easier determination of codeine in human plasma is based on "high-performance" liquid chromatography for separation and the natural fluorescence of codeine for detection. Codeine is extracted from alkalinized plasma with a mixture of hexane and dichloromethane, and the extract is further purified and chromatographed. The method can be used for routine assay of codeine at the concentrations of 10 micrograms/L or greater in human plasma. As little as 4 micrograms/L can be detected. Coefficients of variation for the assay of codeine in the concentration range of 10 to 100 micrograms/L were 2.2-7.4% (n = 6). We used this method to establish a concentration/time profile for plasma from a human volunteer after a 60-mg oral dose of codeine sulfate.
منابع مشابه
Determination of codeine in human plasma by high-performance liquid chromatography with fluorescence detection.
A rapid, reliable and rugged assay for determining codeine in human plasma using reversed-phase high-performance liquid chromatography with fluorescence detection was developed. This analytical method utilized an ion-exchange/mixed-mode solid-phase extraction procedure. The chromatographic separation was achieved using a 150 x 4.6 mm I.D., 3-microns reversed-phase C8 (deactivated for basic anal...
متن کاملDetermination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....
متن کاملDetermination of codeine and morphine in human plasma by high performance liquid chromatography with serial electrochemical detection.
A method is described for the determination of codeine and its metabolite, morphine, at low nanogram concentrations in plasma. Analysis is accomplished by high-performance liquid chromatography utilizing a cyanopropyl normal bonded phase (NBP) column in reversed-phase mode and two electrochemical detectors in series configuration. Two internal standards are utilized, ethyl morphine for codeine ...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 28 5 شماره
صفحات -
تاریخ انتشار 1982