Pulse parameter uncertainty analysis
نویسندگان
چکیده
A detailed uncertainty analysis is presented for the pulse parameter measurement service of the National Institute of Standards and Technology (NIST, USA). It relates to the new pulse parameter measurement and extraction processes. Uncertainties for pulse amplitude, transition duration, overshoot and undershoot (preshoot) are given. Effects of temperature variation, impulse response estimate, pulse parameter extraction algorithms, time-base distortion, calibration procedures and the waveform reconstruction process are included.
منابع مشابه
Time Frequency Analysis of Higher Harmonic Generation in a Three Color Laser Pulse
high harmonic generation is a useful tool for the generation of short, intense attosecond pulses. In order to simulate high harmonic generation, we performed a numerical solution to the time dependent Schrödinger equation. by considering dipole approximation, we predicted generation of a 53 attosecond pulse. In order to see the time and frequency of emission of attosecond pulse, we exploit...
متن کاملWavelet-based Analysis for Pulse Period of Earthquake Ground-motions
Pulse period of earthquake records has been known as a key parameter in seismology and earthquake engineering. This paper presents a detailed characterization of this parameter for a special class of earthquake records called pulse-like ground motions. This type of motions often resulting from directivity effects is characterized by a strong pulse in the velocity time history of motion, in norm...
متن کاملOptimisation of wire-cut EDM process parameter by Grey-based response surface methodology
Wire electric discharge machining (WEDM) is one of the advanced machining processes. Response surface methodology coupled with Grey relation analysis method has been proposed and used to optimise the machining parameters of WEDM. A face centred cubic design is used for conducting experiments on high speed steel (HSS) M2 grade workpiece material. The regression model of significant factors such ...
متن کاملWater Spray Evaporative Cooling at System Pressures Below the Triple Point
............................................................................................................................... i ACKNOWLEDGEMENTS ....................................................................................................... ii LIST OF FIGURES .................................................................................................................. vi LIST OF T...
متن کاملUncertainty and Ambiguity in Terahertz Parameter Extraction and Data Analysis
and Data Analysis Matthias Krüger, Stefan Funkner, Erik Bründermann, Martina Havenith∗ Ruhr-Universität Bochum, Physikalische Chemie II, NC7/72, D-44780 Bochum, Germany Abstract Phase sensitive measurement techniques, such as THz time-domain spectroscopy or dispersive Fourier transform spectroscopy, are very useful tools to obtain a complete set of optical material parameters. When recording th...
متن کامل