Randomized trial of paclitaxel- and sirolimus-eluting stents in small coronary vessels.
نویسندگان
چکیده
AIMS Sirolimus- and paclitaxel-eluting stents effectively reduce restenosis in small coronary vessels. The relative efficacy of these drug-eluting stents in this high-risk subset is not known. METHODS AND RESULTS A total of 360 patients undergoing percutaneous coronary intervention for de novo lesions in native coronary vessels with a diameter of <2.80 mm received randomly paclitaxel-eluting stents (n=180) or sirolimus-eluting stents (n=180). The primary endpoint was in-stent late luminal loss. Secondary endpoints were angiographic restenosis and need of target lesion revascularization. The study intended to show that the paclitaxel-eluting stent is not inferior to the sirolimus-eluting stent with respect to the primary endpoint. The non-inferiority margin was set at 0.16 mm. Follow-up angiography was performed in 87% of the patients. In-stent late luminal loss in the paclitaxel-eluting stent group was 0.32 mm (upper 95% boundary, 0.42 mm), which was greater than that in the sirolimus-eluting stent group, failing to show the non-inferiority of the paclitaxel-eluting stent to the sirolimus-eluting stent (P>0.99). Angiographic restenosis was found in 19.0% of the lesions in the paclitaxel-eluting stent group and 11.4% of the lesions in the sirolimus-eluting stent group (P=0.047). Target lesion revascularization was performed in 14.7% of the lesions treated with paclitaxel-eluting stents and 6.6% of the lesions treated with sirolimus-eluting stents (P=0.008). CONCLUSION The paclitaxel-eluting stent is associated with a greater late luminal loss and is less effective in reducing restenosis in small coronary vessels than the sirolimus-eluting stent.
منابع مشابه
Impact of vessel size on outcome after implantation of sirolimus-eluting and paclitaxel-eluting stents: a subgroup analysis of the SIRTAX trial.
OBJECTIVES We assessed the impact of vessel size on angiographic and long-term clinical outcome after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) within a randomized trial (SIRTAX [Sirolimus-Eluting Stent Compared With Paclitaxel-Eluting Stent for Coronary Revascularization]). BACKGROUND Percutaneous coronary intervention in...
متن کاملRationale and design for the PAINT randomized trial.
BACKGROUND We describe the rationale and design for the 'PercutAneous INTervention with biodegradable-polymer based paclitaxel-eluting or sirolimus-eluting versus bare stents for de novo coronary lesions - PAINT trial'. OBJECTIVES To evaluate two novel formulations of paclitaxel-eluting stent and the sirolimus-eluting stent against a stent with the same metallic structure but without polymer ...
متن کاملComparison of paclitaxel- and sirolimus-eluting stents in everyday clinical practice: the SORT OUT II randomized trial.
CONTEXT Approval of drug-eluting coronary stents was based on results of relatively small trials of selected patients; however, in routine practice, stents are used in a broader spectrum of patients. OBJECTIVE To compare the first 2 commercially available drug-eluting stents-sirolimus-eluting and paclitaxel-eluting-for prevention of symptom-driven clinical end points, using a study design ref...
متن کاملنتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت
Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...
متن کاملImpact of lesion length and vessel size on clinical outcomes after percutaneous coronary intervention with everolimus- versus paclitaxel-eluting stents pooled analysis from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials.
OBJECTIVES The aim of this study was to investigate the impact of reference vessel diameter (RVD) and lesion length (LL) on the relative safety and efficacy of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES). BACKGROUND Lesion length and RVD are well-known predictors of adverse events after percutaneous coronary intervention. METHODS Patient-level data were pooled from t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal
دوره 27 3 شماره
صفحات -
تاریخ انتشار 2006