Reliability of Measuring Subcutaneous Fat Tissue Thickness Using Ultrasound in Non-Athletic Young Adults.
نویسندگان
چکیده
BACKGROUND Obesity is a major health burden worldwide. A method of assessing uncompressed subcutaneous adipose tissue thickness (USATT) using ultrasound is widely used in sports medicine. However, studies on the reliability of the method in non-athletic people are lacking. We aim to determine the reliability of the human observer in measuring the USATT in non-athletic people. MATERIAL AND METHOD Two young non-athletic, volunteers, having normal body mass, one male (24 years, BMI=21.6 kg/m2) and one female (31 years, BMI=20.73 kg/m2) were measured by 15 observers, 3 times, in 3 gender specific sites. There were 7 expert observers and 8 novices. We used a Hosand BX 2000 Ultrasonic Adipometer to measure USATT. OUTCOMES 91% of the measurement's deviations from the mean were between -4 and 4 mm. Variance of deviation from mean measurements for novices was 5.93 mm, while for experts it was 5.40 mm. Standard error of measurement (SEM) and intraclass correlation coefficient (ICC) for calculated body fat percentage (BF%) (intra-observer SEM=0.78, ICC=0.98; inter-observer SEM=0.45, ICC=0.99) and for all the USATT measurements (intra-observer SEM=0.54, ICC=0.98; inter-observer SEM=0.75, ICC=0.96), showed excellent reliability. The expert observers showed slightly higher ICC and lower SEM values compared to novices. CONCLUSION The intra and inter-observer reliability of the adipometer was very good in measuring the USATT. There was no notable difference between expert and novice observers, thus suggesting that the method can be reliably used by anyone after a brief training, for both research and clinical practice.
منابع مشابه
A novel method for measuring subcutaneous adipose tissue using ultrasound in children - interobserver consistency.
BACKGROUND Currently, sufficiently accurate field methods for body composition assessment in children are missing. The ultrasound method for assessing adipose tissue thickness has been used extensively in sport medicine. However, there are no studies looking at the reliability of this method in non-athletic children. This paper aims to determine the inter-observer reliability in measuring the u...
متن کاملاندازهگیری ضخامت چربی زیرپوستی در تصاویر مادون قرمز در لیپوساکشن: گزارش کوتاه
Background: Currently, there are many techniques to measure subcutaneous body fat but these methods have many limitations. In this study, we tried to provide a clustering algorithm to measure the thickness of subcutaneous fat in thermography images. Methods: For the detection of subcutaneous adipose tissue in the midline area (from pubis to the xiphoid process), imaging takes place in the righ...
متن کاملExamination of the law of grotthus-draper: does ultrasound penetrate subcutaneous fat in humans?
One benefit of ultrasound over infrared modalities is its ability to penetrate subcutaneous fat. The purpose of this study was to compare tissue temperature rise during ultrasound treatments in humans with various thicknesses of subcutaneous fat in the medial gastrocnemius. Twenty males served as subjects. A 23-gauge hypodermic needle microprobe was inserted 3-cm deep into the medial portion of...
متن کاملAnterior thigh composition measured using ultrasound imaging to quantify relative thickness of muscle and non-contractile tissue: a potential biomarker for musculoskeletal health.
This study aimed to use ultrasound imaging to provide objective data on the effects of ageing and gender on relative thickness of quadriceps muscle and non-contractile tissue thickness (subcutaneous fat, SF, combined with perimuscular fascia). In 136 healthy males and females (aged 18-90 years n = 63 aged 18-35 years; n = 73 aged 65-90) images of the anterior thigh (dominant) were taken in rela...
متن کاملRelative and absolute reliability of ultrasound measurements for the thickness of the soft tissue around the shoulder joint of young normal subjects
[Purpose] The purpose of this study was to examine the reliability of ultrasound measurements by analyzing the relative reliability and absolute reliability when measuring soft tissue thickness around the shoulder joint. [Subjects and Methods] Eleven healthy young adults (22 shoulders) participated in this study. Thickness of the supraspinatus tendon, subacromial bursa, and biceps tendon was me...