Floor-supply Displacement Ventilation for Workshops

نویسندگان

  • Josephine Lau
  • Qingyan Chen
  • Ray W. Herrick
چکیده

This paper reported the investigation of the performance of floor-supply displacement ventilation with swirl diffusers or perforated panels under a high cooling load (nearly 90W/m). The experiment was carried out in a full-scale environmental chamber to obtain reliable data on the floor-supply displacement ventilation for the validation of a computational-fluid-dynamics (CFD) program. Numerical simulations using CFD program were to evaluate the performance of the system for a large workshop. The impacts of several parameters, such as the air change rate, number of diffusers, diffuser location, occupant location, furniture arrangement, partition location, and arrangement of exhausts, on the indoor environment were investigated based on the thermal comfort level and indoor air quality. This study ranked the impacts of these parameters on indoor environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy Analysisf for Workshops with Floor-supply Displacement Ventilation under the U.s. Climates

Many studies have shown that floor-supply displacement ventilation systems are better than mixing ventilation systems. The benefits include indoor air quality, thermal comfort, and reduced energy use. The energy benefits depend on the climate conditions. This research compared the energy use of a floor-supply displacement ventilation system in a large industrial workshop with that of a mixing v...

متن کامل

Floor-Supply Displacement Ventilation in a Small Office

This paper studied the performance of a floor-supply displacement ventilation system using computational-fluid-dynamics (CFD). The experiment was carried out in a full-scale environmental chamber with a floor-supply system to obtain reliable flow information for the validation of a CFD program. The validated program was used further to evaluate the performance of the floor-supply displacement v...

متن کامل

Effect of opening diffuser and return vent location on air quality, thermal comfort and energy saving in desk displacement ventilation (DDV) system

Many investigations have recently been performed on return vent height and indicate that having 1.3 m distance from the floor is the optimized height for it. In this article, the effect of distance between opening diffuser and return vent on air quality, thermal comfort and energy saving was investigated. According to the results, by increasing the distance between opening and return vent up to...

متن کامل

Comparison of airflow and contaminant distributions in rooms with traditional displacement ventilation and under-floor air distribution systems

Traditional displacement ventilation (TDV) and under-floor air distribution (UFAD) systems have been used widely because they create better indoor air quality. Many previous studies have compared the TDV or UFAD systems with mixing ventilation systems. This study first compared experimentally the TDV with UFAD systems that use four different diffusers (perforated TDV diffusers, swirl diffusers,...

متن کامل

Numerical Investigation of Indoor Air Quality and Thermal Comfort in a Ventilated Room

Understanding the behavior of airflow in a room is essential for building designers to provide the most efficient design of ventilation system, and having acceptable indoor air quality. This trend is the motive to solve the relationship between airflow parameters and thermal comfort. This paper investigates airflow characteristics, indoor air quality (IAQ), and the thermal comfort (TC) in a ven...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006