In-vitro comparison of LC-DCP- and LCP-constructs in the femur of newborn calves – a pilot study
نویسندگان
چکیده
BACKGROUND To compare the biomechanical in-vitro characteristics of limited-contact dynamic compression plate (LC-DCP) and locking compression plate (LCP) constructs in an osteotomy gap model of femoral fracture in neonatal calves. Pairs of intact femurs from 10 calves that had died for reasons unrelated to the study were tested. A 7-hole LC-DCP with six 4.5 mm cortical screws was used in one femur and a 7-hole LCP with four 5.0 mm locking and two 4.5 mm cortical screws was used in the corresponding femur. The constructs were tested to failure by cyclic compression at a speed of 2 mm/s within six increasing force levels. RESULTS The bone-thread interface was stripped in 21 of 80 cortical screws (26.3%) before a pre-set insertion torque of 3 Nm was achieved. Only 3 corresponding intact pairs of constructs could be statistically compared for relative structural stiffness, actuator excursion and width of the osteotomy gap. Relative structural stiffness was significantly greater, actuator excursion and width of the osteotomy gap were significantly smaller in the LCP constructs. While failure occurred by loosening of the screws in the LC-DCP constructs, locking constructs failed by cutting large holes in the soft distal metaphyseal bone. CONCLUSIONS An insertion torque sufficient to provide adequate stability in femurs of newborn calves could not be achieved reliably with 4.5 mm cortical screws. Another limiting factor for both constructs was the weak cancellous bone of the distal fracture fragment. LCP constructs were significantly more resistant to compression than LC-DCP constructs.
منابع مشابه
Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware
BACKGROUND Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence") utilizing conventional (non-locked) implants in comparison to conventional LC-DCP (limited contact dynamic com...
متن کاملSingle cycle to failure in torsion of three standard and five locking plate constructs.
OBJECTIVES The biomechanical properties of standard plates and recently designed locking plates were compared in torsion. We hypothesized that titanium (Ti) constructs would have the greatest deformation, and String of Pearls (SOP) constructs the greatest strength and stiffness. METHODS Dynamic compression plates (DCP), stainless steel (SS) limited contact (LC)-DCP, Ti LC-DCP, locking compres...
متن کاملA Case-Control Study of Association between Diarrhea in Newborn Calves and Infection with Rotavirus and Coronavirus in Some Industrial Dairy Herds of Mashhad Aarea, Iran in 2008
A 1:1 matched case-control study of calves under 1 month of age was carried out by weekly visits to 7 dairy farms in Mashhad from May 2008 to October 2008. Fecal samples were collected from a total of 112 calves with clinical signs of diarrhea and from 112 matched animals without clinical signs of diarrhea as assessed by a scoring system. The samples were investigated for the presence of Rotavi...
متن کاملInternal fixation of fractures of both bones forearm: Comparison of locked compression and limited contact dynamic compression plate
BACKGROUND The locking compression plate (LCP) with combination holes is a newer device in fracture fixation. We undertook a study comparing the LCP with limited contact dynamic compression plate (LC-DCP) in the treatment of diaphyseal fractures of both bones of the forearm. MATERIALS AND METHODS This is a prospective comparative study, 36 patients (18 in each group) with fractures of both th...
متن کاملComparing the In Vitro Stiffness of Straight-DCP, Wave-DCP, and LCP Bone Plates for Femoral Osteosynthesis
The objective of this study was to compare the Locking Compression Plate (LCP) with the more cost-effective straight-dynamic compression plate (DCP) and wave-DCPs by testing in vitro the effects of plate stiffness on different types of diaphyseal femur fractures (A, B, and C, according to AO classification). The bending structural stiffness of each plate was obtained from four-point bending tes...
متن کامل