Closing sounds and related complaints after heart valve replacement with St Jude Medical, Duromedics Edwards, Björk-Shiley Monostrut, and Carbomedics prostheses.

نویسندگان

  • A Moritz
  • U Steinseifer
  • G Kobinia
  • K Neuwirth-Riedl
  • H Wolters
  • H Reul
  • E Wolner
چکیده

OBJECTIVE To measure the noise produced and related subjective complaints after implantation of four different mechanical heart valve prostheses and to identify further factors related to the patient and prosthesis that influence noise generation and complaints. DESIGN Sound pressure was measured 5 and 10 cm and 1 m from the point of maximal impulse on the body surface by a calibrated meter in quiet rooms with either a decibel(A) filter or octave filters. The patients were asked about their complaints and examined physically. SETTING The measurements were conducted in silent rooms of ear, nose, and throat departments. The patients had been operated on either in a university hospital or a community hospital. MAIN OUTCOME MEASURES Sound pressures of frequency bands and sound pressures measured in dB(A) at various distances. Complaints registerd were: sleep disturbance, disturbance during daytime, "wants a less noisy prosthesis," and "can hear the closing click". PATIENTS 143 patients after heart valve replacement with St Jude Medical (n = 35), Duromedics Edwards (n = 38), Carbomedics (n = 34) and Björk-Shiley Monostrut (n = 36) prostheses operated on between 1984 and 1988 were matched for valve position, ring size, and body surface area. RESULTS Duromedics Edwards (33.5 (6) dB(A)) and Björk-Shiley Monostrut valves (31 (4) dB(A)) were significantly louder than St Jude Medical (24 (4) dB(A)) and Carbomedics (25 (6) dB(A)) prostheses (p = 0.0001) (mean (SD)). The louder valves were significantly more often heard by the patients (p = 0.0012) and caused more complaints both during sleep (p = 0.024) and during the daytime (p = 0.07). Patients with these valves were more likely to want a less noisy valve (p = 0.0047). Patients with symptoms were younger, had better hearing, and were more likely to be in sinus rhythm. As well as the type of prostheses, the valve diameter and body height also had an effect on sound emission. CONCLUSIONS The intensity of the closing click of mechanical valve prostheses was significantly different for various designs. Patient complaints were related to the objectively measured sound pressure. Noise production should be considered when a mechanical valve is selected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical performance of biological and mechanical prostheses.

Prosthetic valve replacement remains the most viable alternative for the treatment of severely diseased heart valves. The cumulative experience of mechanical protheses and bioprostheses was evaluated for a 10-year performance comparison: Carpentier-Edwards standard porcine bioprosthesis (CE-S), 1,214 operations; Carpentier-Edwards supraannular porcine bioprosthesis (CE-SAV), 2,489; and mechanic...

متن کامل

Echocardiographic assessment of left ventricular filling characteristics after mitral valve replacement with the St Jude medical prosthesis.

The major cause of late mortality and morbidity after prosthetic valve replacement is thromboembolism. The nidus for initiation of thrombus formation has been blood metal interfaces, and a new valve--the St Jude prosthesis--has therefore been developed without any metal components. We have assessed echocardiographically in 27 patients the effects of this valve on left ventricular filling charac...

متن کامل

Auscultatory characteristics of normally functioning Lillehei-Kaster, Björk-Shiley, and St Jude heart valve prostheses.

Auscultatory and echocardiographic and phonocardiographic studies were performed on 26 patients who had a total of 11 Lillehei-Kaster, 16 Björk-Shiley, and 18 St Jude heart valve prostheses functioning normally in the aortic or mitral positions or both. With all types and positions of prostheses a distinct closing sound was always detected. It was frequently heard in two parts which, according ...

متن کامل

Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.

Seventy-four patients with single prosthetic valves (Björk-Shiley or Starr-Edwards) in the mitral or aortic position and 18 controls with rheumatic valvar heart disease were investigated for evidence of intravascular haemolysis. Serum lactate dehydrogenase (LDH) was used as the most sensitive indicator of haemolysis. Raised concentrations were found in a third of 39 patients with Björk-Shiley p...

متن کامل

Hemodynamics alterations induced by isoproterenol and pacing after aortic valve replacement with the Björk-Shiley or St. Jude medical prosthesis.

Stress evaluation was carried out in 26 patients approximately 7 months after aortic valve replacement with Björk-Shiley valves (13 patients) and St. Jude medical valves (13 patients). During isoproterenol infusion (0.3 micrograms/kg/min), cardiac output increased by a factor of 1.5 and aortic valve area decreased by 50% for both valve groups, while transvalvular gradients (rest: 7 +/- 2 vs 10 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 67 6  شماره 

صفحات  -

تاریخ انتشار 1992