Assessment and improvement of image homogeneity in black-blood T2-weighted turbo spin-echo CMR
نویسندگان
چکیده
Background Double inversion recovery (DIR) and triple inversion recovery (TIR) prepared Turbo-Spin-Echo (TSE) are the most commonly used sequences for black-blood T2weighted (T2W) cardiac magnetic resonance. For both, cardiac motion often leads to signal loss and image inhomogeneity, which can affect diagnosis. Signal loss artifacts are thought to be due to misalignment of the black-blood preparation with readout. However, the TSE readout itself is also motion sensitive and could lead to signal loss. We examined image homogeneity in routine Black-Blood T2W-TSE and investigated potential improvement by reducing interecho-spacing of the TSE readout.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملCardiac magnetic resonance imaging using an open 1.0T MR platform: a comparative study with 1.5T
Background Cardiac MRI (cMRI) has evolved as the non-invasive reference standard for accurate and highly reproducible determination of cardiac function and myocardial viability. Thus, cMRI is widespread and increasingly utilized in the clinical practice. The introduction of open high-field (HFO) MR scanners offers advantages not only for imageguided interventions, examinations of patients with ...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملLumbar degenerative disk disease: prospective comparison of conventional T2-weighted spin-echo imaging and T2-weighted rapid acquisition relaxation-enhanced imaging.
PURPOSE To compare conventional T2-weighted spin-echo imaging with a rapid acquisition relaxation enhanced (RARE) technique in the routine evaluation of lumbar degenerative disk disease. METHODS Thirty consecutive patients referred for evaluation of the lumbar spine for suspected degenerative disk disease were evaluated with sagittal and axial T1-weighted spin-echo, conventional T2-weighted s...
متن کاملDiagnostic performance of T2-weighted CMR for evaluation of acute myocardial injury
Background Edema-sensitive T2-weighted cardiac magnetic resonance (CMR) based on fast spin-echo (FSE) imaging is a useful modality to detect acute myocardial injury. Conventional T2-weighted CMR uses three inversion-recovery (IR) pulses, the first two to null the blood signal, and the last one (STIR) to null fat signal, but suffers from reduced myocardial signal and signal dropout. We compared ...