Quantitating the effect of prosthesis design on femoral remodeling using high‐resolution region‐free densitometric analysis (DXA‐RFA)

نویسندگان

  • Mohsen Farzi
  • Richard M. Morris
  • Jeannette Penny
  • Lang Yang
  • Jose M. Pozo
  • Søren Overgaard
  • Alejandro F. Frangi
  • Jeremy Mark Wilkinson
چکیده

Dual energy X-ray absorptiometry (DXA) is the reference standard method used to study bone mineral density (BMD) after total hip arthroplasty (THA). However, the subtle, spatially complex changes in bone mass due to strain-adaptive bone remodeling relevant to different prosthesis designs are not readily resolved using conventional DXA analysis. DXA region free analysis (DXA RFA) is a novel computational image analysis technique that provides a high-resolution quantitation of periprosthetic BMD. Here, we applied the technique to quantitate the magnitude and areal size of periprosthetic BMD changes using scans acquired during two previous randomized clinical trials (2004 to 2009); one comparing three cemented prosthesis design geometries, and the other comparing a hip resurfacing versus a conventional cementless prosthesis. DXA RFA resolved subtle differences in magnitude and area of bone remodeling between prosthesis designs not previously identified in conventional DXA analyses. A mean bone loss of 10.3%, 12.1%, and 11.1% occurred for the three cemented prostheses within a bone area fraction of 14.8%, 14.4%, and 6.2%, mostly within the lesser trochanter (p < 0.001). For the cementless prosthesis, a diffuse pattern of bone loss (-14.3%) was observed at the shaft of femur in a small area fraction of 0.6% versus no significant bone loss for the hip resurfacing prosthesis (p < 0.001). BMD increases were observed consistently at the greater trochanter for all prostheses except the hip-resurfacing prosthesis, where BMD increase was widespread across the metaphysis (p < 0.001). DXA RFA provides high-resolution insights into the effect of prosthesis design on the local strain environment in bone. © 2017 The Authors Journal of Orthopaedic Research published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:2203-2210, 2017.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantifying Pelvic Periprosthetic Bone Remodeling Using Dual-Energy X-Ray Absorptiometry Region-Free Analysis

The gold standard tool for measuring periprosthetic bone mineral density (BMD) is dual-energy X-ray absorptiometry (DXA). However, resolution of the method is limited due to the aggregation of pixel data into large regions of interest for clinical and statistical analysis. We have previously validated a region-free analysis method (DXA-RFA) for quantitating BMD change at the pixel level around ...

متن کامل

Use of densitometric examination after cemented total knee arthroplasty.

Background. Dual energy X-ray absorptiometry (DXA, DEXA) is one of many ways of measuring bone mineral density (BMD). Considering the fact that it is possible using DXA analysis to distinguish metal elements from bone, this method seems to be optimal in the assessment of bone mineral density in the area of an inserted implant. The aim of our study was to examine the usefulness of DXA examinatio...

متن کامل

Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems

BACKGROUND AND PURPOSE Dual-energy X-ray absorptiometry (DXA) analysis of the 7 periprosthetic Gruen zones is the most commonly used protocol to evaluate bone remodeling after the implantation of conventional femoral stems. We assessed the value of DXA after cementless primary total hip arthroplasty (THA) by comparing the effect of progressive shortening of the stem of two femoral implants on p...

متن کامل

Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population

Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...

متن کامل

Investigation of Wear Behavior of Biopolymers for Total Knee Replacements Through Invitro Experimentation

The average life span of knee prosthesis used in Total Knee Replacement (TKR) is approximately 10 to 15 years. Literature indicates that the reasons for implant failures include wear, infection, instability, and stiffness. However, the majority of failures are due to wear and tear of the prosthesis. The most common biopolymer used in TKR  is Ultra High Molecular Weight Polyethylene (UHMWPE). Pr...

متن کامل