Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study.

نویسندگان

  • R Hoffmann
  • C Jansen
  • A König
  • P K Haager
  • G Kerckhoff
  • J vom Dahl
  • V Klauss
  • P Hanrath
  • H Mudra
چکیده

AIMS Histological restenosis models in animals have indicated that stent design has a significant impact on vessel trauma during stent implantation and on the amount of subsequent neointimal tissue proliferation. The impact of different stent designs on intimal hyperplasia in human atherosclerotic coronary arteries has not been determined. METHODS AND RESULTS Angiographic and intravascular ultrasound studies were performed at the 6 month follow-up in 131 consecutive native coronary lesions of 131 patients treated with 50 Multi-Link stents, 40 InFlow stents and 41 Palmaz-Schatz stents. Lumen and stent cross-sectional areas (CSA) were measured at 1 mm axial increments. Mean intimal hyperplasia cross-sectional area (stent CSA-lumen CSA) and mean intimal hyperplasia thickness were calculated. Intravascular ultrasound demonstrated different levels of intimal hyperplasia proliferation for the three stents. Mean intimal hyperplasia thickness was 0.16+/-0.08 mm for Multi-Link stents, 0.26+/-0.19 mm for Palmaz-Schatz stents and 0.39+/-0.14 mm for Inflow stents (P<0.001). Multivariate analysis proved that stent type was the only independent predictor of intimal hyperplasia thickness at follow-up (P<0.001). CONCLUSION Coronary stent design has a significant impact on subsequent intimal hyperplasia after implantation into atherosclerotic human coronary arteries. The corrugated ring design of the Multi-Link stent proved to result in less tissue proliferation at 6-month follow-up than the tubular slotted design of Palmaz-Schatz and InFlow stents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cytomegalovirus, Chlamydia pneumoniae, and Helicobacter pylori IgG antibodies and restenosis after stent implantation: an angiographic and intravascular ultrasound study.

OBJECTIVE To determine the impact of previous infection with cytomegalovirus, Chlamydia pneumoniae, and Helicobacter pylori on neointimal proliferation after coronary angioplasty with stent implantation. DESIGN The study population was made up of 180 patients who had stent implantation in a native coronary artery with systematic angiographic and intravascular ultrasound (IVUS) follow up at si...

متن کامل

Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study.

BACKGROUND Restenosis remains an important limitation of interventional cardiology. Therefore, we aimed to determine the safety and efficacy of sirolimus (a cell-cycle inhibitor)-coated BX Velocity stents. METHODS AND RESULTS Thirty patients with angina pectoris were electively treated with 2 different formulations of sirolimus-coated stents (slow release [SR], n=15, and fast release [FR], n=...

متن کامل

Effects of gold coating of coronary stents on neointimal proliferation following stent implantation.

Experimental studies suggest a reduced neointimal tissue proliferation in vascular stainless steel stents coated with gold. This prospective multicenter trial evaluated the impact of gold coating on neointimal tissue proliferation in patients undergoing elective stent implantation. The primary end point was the in-stent tissue proliferation measured by intravascular ultrasound at 6 months compa...

متن کامل

[Randomized intravascular ultrasound comparison between endoprostheses with and without amorphous silicon-carbide].

The superiority of coronary stent implantation over percutaneous transluminal balloon angioplasty in virtually all lesion subsets has led to the wide use of stents for the percutaneous treatment of coronary lesions 1,2. However, in-stent restenosis remains as a major limitation 3,4. Recent data suggest that neointimal proliferation, the cornerstone of in-stent restenosis 5,6, is related to the ...

متن کامل

Stent Evaluation with Optical Coherence Tomography

Optical coherence tomography (OCT) has been recently applied to investigate coronary artery disease in interventional cardiology. Compared to intravascular ultrasound, OCT is able to visualize various vascular structures more clearly with higher resolution. Several validation studies have shown that OCT is more accurate in evaluating neointimal tissue after coronary stent implantation than intr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 22 21  شماره 

صفحات  -

تاریخ انتشار 2001