PicoWatt infrared power measurement using an absolute cryogenic radiometer

نویسنده

  • S. M. Carr
چکیده

We report on initial measurements of the low-temperature thermal properties of a device that is similar to the experimental apparatus used for absolute cryogenic radiometry (ACR) within the Low Background InfraRed (LBIR) facility at NIST. The device consists of a receiver cavity mechanically and thermally connected to a temperature-controlled stage through a thin-walled polyimide tube which serves as a weak thermal link. In order to evaluate the functionality of the device for use in a cryogenic radiometer, we measured the thermal resistance and thermal time constant of the system within the temperature range of 1.8 4.4 K. The measured thermal resistance and thermal time constant at 1.883 K were 2400 ± 500 (K/mW) and 24 ± 6 (s). This value for the thermal resistance should result in about an order-of-magnitude improvement in radiometer sensitivity compared with the present ACR within LBIR. Although the sensitivity should improve by about an order-of-magnitude, the measured time constant is nearly unchanged with respect to previous ACRs within LBIR, due to the reduced dimensions of the receiver cavity. Finally, the thermal conductivity inferred from the measured thermal resistance and geometrical parameters was computed, with an average value of 0.015 (W/m-K), and compared with other measurements of polyimide from the literature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intercomparison of the LBIR Absolute Cryogenic Radiometers to the NIST Optical Power Measurement Standard

The Low Background Infrared calibration (LBIR) facility at the National Institute of Standards and Technology (NIST) presently maintains four absolute cryogenic radiometers (ACRs) which serve as standard reference detectors for infrared calibrations performed by the facility. The primary standard for optical power measurements at NIST-Gaithersburg has been the High Accuracy Cryogenic Radiometer...

متن کامل

Cryogenic Blackbody Calibrations at the National Institute of Standards and Technology Low Background Infrared Calibration Facility

National Institute of Standards and Technology, Gaithersburg, MD 20899-0001 The Low Background Infrared Calibration Facility (LBIR) at the National Institute of Standards and Technology has been in operation for calibration measurements of ihe radiant power emitted fn>rn infrared radiation (IR) sources, such as cryogenic blaclcbodies, for more than 2 years. The IR sources arc sent to NIST by Cu...

متن کامل

Low-Background Temperature Calibration of Infrared Blackbodies

The stability of blackbody sources and their ability to be modeled accurately make them well suited for radiometric calibration activity. However, the implementation of the blackbody in industry or the laboratory may, and often does result in blackbody performance that deviates from ideal. The Low Background Infrared (LBIR) facility at the National Institute of Standards and Technology (NIST) w...

متن کامل

Improved Near-Infrared Spectral Responsivity Scale

A cryogenic radiometer-based system was constructed at the National Institute of Standards and Technology for absolute radiometric measurements to improve detector spectral power responsivity scales in the wavelength range from 900 nm to 1800 nm. In addition to the liquid-helium-cooled cryogenic radiometer, the system consists of a 100 W quartz-tungsten-halogen lamp light source and a 1 m singl...

متن کامل

The TSI Radiometer Facility - absolute calibrations for total solar irradiance instruments

The total solar irradiance (TSI) climate data record includes overlapping measurements from 10 spaceborne radiometers. The continuity of this climate data record is essential for detecting potential long-term solar fluctuations, as offsets between different instruments generally exceed the stated instrument uncertainties. The risk of loss of continuity in this nearly 30-year record drives the n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009