How sensitive are immunometric assays for thyrotropin?

نویسندگان

  • M G McConway
  • R S Chapman
  • G H Beastall
  • E Brown
  • J Tillman
  • J A Bonar
  • A Hutchison
  • T Allison
  • J Finlayson
  • R Weston
چکیده

The usual method for calculation of the "sensitivity" of thyrotropin immunometric assays is multireplicate analysis of the zero analyte standard. Although this is a statistically valid estimate of the scatter likely to be found in the response variable, it is unrelated to normal analytical practice (usually analysis in duplicate) and estimates intra-assay errors only. This study was designed to assess the analytical performance of 10 immunometric assays used routinely for measurement of thyrotropin in human serum. Response data from each assay were accumulated to provide (a) an estimate of "sensitivity" from multireplicate analysis and (b) an estimate of "minimum detection limit," relating directly to errors associated with routine performance and derived from a minimum of 500 duplicate analyses. We conclude that the "minimum detection limit" should be promoted as a more meaningful measure of assay performance at low analyte concentrations than the "sensitivity" derived from multireplicate analysis of the zero-analyte standard.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunoradiometric and luminescence immunoenzymometric assay of human thyrotropin from dried blood spots for screening of neonatal hypothyroidism.

Two monoclonal antibodies to thyrotropin prepared in our laboratory were employed for the development of two-site immunometric assays in two modifications for the estimation of human thyrotropin in dried blood spots designed for the screening of neonatal hypothyroidism. The immunoradiometric assay using the second antibody labelled with 125I is simple and fast (one incubation step lasting 2 h)....

متن کامل

Two sensitive immunometric assays for serum thyroid stimulating hormone evaluated.

This study was conducted to evaluate the analytical performance (functional sensitivity, reproducibility, parallelism, and accuracy) of two recent commercial kits marketed as third generation immunometric assays for measuring serum thyroid stimulating hormone (TSH). One assay is automated; the other is manual. Accuracy by method comparisons was evaluated using 86 patient samples assayed by an e...

متن کامل

Interlaboratory/intermethod differences in functional sensitivity of immunometric assays of thyrotropin (TSH) and impact on reliability of measurement of subnormal concentrations of TSH.

Clinically relevant interassay precision profiles for thyrotropin (thyroid-stimulating hormone; TSH) were constructed with human serum pools measured over 4-8 weeks by six immunometric assays, in at least two different reagent lots. Functional sensitivities (the concentration at which the interassay CV is < or = 20%) were determined in four to eight clinical laboratories plus the respective man...

متن کامل

The role of precision in determining the performance of a thyrotropin assay in diagnosing hyperthyroidism.

We examined the relationship between analytical sensitivity, precision at the lower limit of the reference interval, and diagnostic performance in hyperthyroidism for one radioimmunoassay and five immunometric assay kits for thyrotropin. The analytical sensitivity of these kits extended from 0.05 to 1.56 milli-int. units/L. Diagnostic efficiencies of the immunometric assays, in discriminating b...

متن کامل

Interassay variability of immunometric methods for thyrotropin in an external quality assessment survey: evidence that functional sensitivity is not always adequate for clinical decisions.

We investigated the ability of current immunometric methods for thyrotropin (TSH; thyroid-stimulating hormone) to distinguish between low-normal and subnormal hormone concentrations by using the data from an external quality assessment (EQA) survey in 1990. We computed the interassay (between-run) precision profiles from results from 101 laboratories, which used the five most popular kits in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 1989