Bradycardia-dependent rise in the atrial capture threshold early after cardiac pacemaker implantation in patients with sick sinus syndrome☆☆☆
نویسندگان
چکیده
Akira Kimata, MD, Kentaro Yoshida, MD, Noriyuki Takeyasu, MD, Rieko Nakagami, MD, Jun Osada, MD, Takeshi Mitsuhashi, MD, Kazutaka Aonuma, MD, Akihiko Nogami, MD From the Cardiovascular Division, Ibaraki Prefectural Central Hospital, Kasama, Japan, Cardiovascular Division, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan, Department of Cardiology, Saiseikai Utsunomiya Hospital, Utsunomiya, Japan, Department of Cardiology, Yokosuka General Hospital Uwamachi, Yokosuka, Japan, and Department of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, Saitama, Japan.
منابع مشابه
A case of delayed cardiac perforation of active ventricular lead
A 65-year-old man was admitted as for one month of repetitive dizziness and one episode of syncope. Electrocardiogram showed sinus bradycardia and his Holter monitoring also showed sinus bradycardia with sinus arrest, sino-atrial block and a longest pause of 4.3 s. Then sick sinus syndrome and Adam-Stokes syndrome were diagnosed. Then a dual chamber pacemaker (Medtronic SDR303) was implanted an...
متن کاملPeriprocedural cardiac troponin elevation: a potential indicator of enhanced ventricular threshold in permanent pacemaker recipients
Background and aim: Permanent cardiac pacing is the most efficient treatment for patients with symptomatic bradycardia and high-degree atrioventricular (AV) block. For effective pacing, sensing and pacemaker battery longevity; ventricular pacing threshold (VPT) levels, lead impedance levels and Rwave amplitude levels must be desirable. We aimed to search the association between elevated serum t...
متن کاملIschemic stroke after cardiac pacemaker implantation in sick sinus syndrome.
The risk of embolic stroke during sick sinus syndrome before cardiac pacemaker insertion is substantial, but stroke after pacemaker insertion has not been well studied. We observed 10 sick sinus syndrome patients who developed an ischemic stroke 4 days to 112 months after pacemaker insertion. Nine patients represented 6% of the 156 ischemic stroke patients observed during a 30-month period. Eig...
متن کاملPacemaker dependency after pacemaker implantation.
BACKGROUND Pacemaker dependency (PD) can be defined as the risk of serious injury or death from sudden pacemaker failure, an event more dangerous than progressive rate decrease. The aim of this study was to evaluate the incidence of PD during long-term follow-up after pacing system implantation. METHODS AND RESULTS The study included 3638 patients (mean age 65.3 +/- 10.2 years). Indications f...
متن کاملRetrospective analysis of reasons for failure of DDD pacemaker implantation in patients operated on between 1993 and 2005.
BACKGROUND During implantation of a DDD pacemaker the following difficulties may be encountered: venous anomalies (the absence of vessels of adequate calibre or difficulty in subclavian vein puncture), arrhythmias during implantation (episodes of atrial flutter/fibrillation while the atrial leads are being positioned), lack of mechanical stability of the electrode in the heart chamber and inabi...
متن کامل