A full compensating system for general loads, based on a combination of thyristor binary compensator, and a PWM-IGBT active power filter
نویسندگان
چکیده
A full compensating system for distribution networks which is able to eliminate harmonics, correct unbalanced loads and generate or absorb reactive power is presented. The system is based on a combination of a Thyristor Binary Compensator (TBC), and a PWM-IGBT Active Power Filter (APF) connected in cascade. The TBC compensates the fundamental reactive power and balances the load connected to the system. The APF eliminates the harmonics and compensates the small amounts of load unbalances or power factor that the TBC cannot eliminate due to its binary condition. The TBC is based on a chain of binary-scaled capacitors and one inductor per phase. This topology allows, with an adequate number of capacitors, a soft variation of reactive power compensation and a negligible generation of harmonics. The capacitors are switched-on when the line voltage reaches its peak value, avoiding inrush currents generation. The inductor helps to balance the load, and absorbs reactive power when required. The APF works measuring the source currents, forcing them to be sinusoidal. The two converters (TBC and APF) work independently, making the control of the system simpler and more reliable. The system is able to respond to many kinds of transient perturbations in no more than a couple of cycles. The paper analyzes the circuit proposed, the way it works and the results obtained under operation with different types of loads.
منابع مشابه
Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads
Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...
متن کاملEffectiveness of DSTATCOM to Compensate the Load Current Harmonics in Distribution Networks under Various Operating Conditions
The Distribution Static Compensator (DSTATCOM) is a compensating device which is used to control the flow of reactive power in the distribution systems. This paper focuses on power quality improvement with DSTATCOM on feeders feeding linear loads, nonlinear loads and DTC induction motor drive. In this paper, effectiveness of DSTATCOM in distribution networks to compensate the load current harmo...
متن کاملDesign and Control of a Novel hybrid Active Power Filter based on Load Harmonic Currents Separation with the aim of DC-link voltage minimization in voltage source converter
This paper proposes a new hybrid active power filter, including voltage source converter (VSC) based active power filter and Thyristor Controllable LC Passive Filter (TCLC-HAPF) for eliminating harmonic load current components and compensating reactive power. This new structure which is based on the separation of high and low-frequency components of load current idea can reduce the drawbacks of...
متن کاملPower filtering method with controllable inductance for eliminating thyristor rectifier load harmonics
In this paper, we propose a Controlled Inductance Power Filter (CIPF) to solve power quality problems in industrial DC power supply systems. This method is based on the theory of magnetic potential equilibrium combined with active hybrid filter technology. Initially the system structure and filter wiring scheme are presented and the equivalent circuit is performed with the mathematical models o...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE Trans. Industrial Electronics
دوره 50 شماره
صفحات -
تاریخ انتشار 2003