Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study

نویسندگان

  • Suparna Ganguly Saha
  • Neelam Vijaywargiya
  • Divya Saxena
  • Mainak Kanti Saha
  • Anuj Bharadwaj
  • Sandeep Dubey
چکیده

Introduction To evaluate the incidence of microcrack formation canal preparation with two rotary nickel-titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. Materials and Methods One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group (n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. Results The highest incidence of microcracks were associated with the ProTaper Next group, 80% (P = 0.00), followed by the Mtwo group, 70% (P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% (P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups (P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups (P = 0.000) as well as the Mtwo and self-adjusting file groups (P = 0.000). Conclusion All nickel-titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Research Paper: Comparison efficacy of calcium hydroxide removal by Revo-s, Protaper Rotary file from root canal

Abstract Introduction: The aim of this study was to evaluate the efficacy of two rotary instrument systems (ProTaper and Revo-s File) in removing calcium hydroxide residues from root canal walls Materials and Methods:Thirty human  maxillary incisors were instrumented with the ProTaper System up to the F2 instrument, irrigated with 2.5% NaOCl,and filled with a calcium hydroxide intracanal dr...

متن کامل

Evaluation of the Fractured Surface of Five Endodontic Rotary Instruments: A Metallurgical Study

INTRODUCTION The aim of this study was to compare several metallurgic properties of Neoniti instrument with four other commonly used endodontic rotary files. METHODS AND MATERIALS Neoniti A1 (25/0.08), RaCe (25/0.06), Mtwo (25/0.06), Twisted file (25/0.06) and ProTaper Next X2 (25/0.06) were examined by differential scanning calorimetry (DSC) before and after heat treatment at 500°C. X-ray di...

متن کامل

Microsoft Word - 11292-meraji 3-4-

ARTICLE INFO ABSTRACT Article Type: Original Article Introduction: The aim of this study was to compare several metallurgic properties of Neoniti instrument with four other commonly used endodontic rotary files. Methods and Materials: Neoniti A1 (25/0.08), RaCe (25/0.06), Mtwo (25/0.06), Twisted file (25/0.06) and ProTaper Next X2 (25/0.06) were examined by differential scanning calorimetry (DS...

متن کامل

In Vitro Evaluation of Dentinal Microcrack Formation during Root Canal Preparations by Different Niti Systems

The purpose of this study was to compare dentinal microcrack formation while using hand ProTaper (PT), ProTaper and ProTaper Next rotary files. Forty single rooted teeth were selected. 10 teeth were left unprepared and served as control, and the remaining 30 teeth were divided into 3 groups. After preparation with the file system selected, roots were sectioned 3, 6, and 9 mm from the apex, and ...

متن کامل

A Comparative SEM Investigation of Smear Layer Remaining on Dentinal Walls by Three Rotary NiTi Files with Different Cross Sectional Designs in Moderately Curved Canals.

OBJECTIVE The objective of this study was to compare the smear layer formed on root canal walls during canal preparation of extracted human teeth by Twisted, Mtwo, and ProTaper rotary nickel titanium instruments. MATERIALS AND METHODS Sixty single rooted human premolar teeth with root curvature <25(0) were selected and randomly divided into three Groups (n= 20 teeth per Group). Three types of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2015