Assessment of exhaled nitric oxide by a new hand-held device.
نویسندگان
چکیده
BACKGROUND Fractional exhaled nitric oxide (FENO) has been implicated as a pulmonary biomarker. The aim of this study was to compare the performance of a new hand-held device to a standard chemiluminescence analyzer and to another portable device. METHODS FENO levels measured by NObreath (Bedfont) were compared to those of (1) a chemiluminescence detector (Logan, Logan Research) and (2) the electrochemical portable NIOX MINO (Aerocrine) in 18 healthy volunteers on three consecutive occasions: in the morning, 1 h and 24 h later. RESULTS Comparing FENO levels obtained by NObreath to those by Logan values were similar and a very close linear relationship was found between the two devices (r = 0.923, p < 0.001). The mean inter-device difference in FENO level was -3.45 ppb and the limits of agreement (Bland-Altman test) were -10.98 and 4.08 ppb. In the second series FENO levels obtained by NObreath were found to be slightly higher compared to those of NIOX MINO, but still showed a close correlation (r = 0.681, p < 0.001). The mean inter-device difference in FENO level was 4.36 ppb and the limits of agreement were -7.38 and 16.1 ppb. Analyzing the repeated FENO measurements, the mean coefficient of variation using NObreath tended to be lower than that of NIOX MINO (16.9 vs. 24.7%, p = 0.059), while it was similar as the value obtained with Logan (11.8 vs. 9.0%, p = 0.342). CONCLUSIONS FENO values measured with NObreath are reproducible and in good agreement with those obtained by NIOX MINO and Logan indicating that NObreath is suitable for use in clinical practice.
منابع مشابه
Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children
BACKGROUND Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary he...
متن کاملReliability of a new hand-held device for the measurement of exhaled nitric oxide.
BACKGROUND Given the importance of airway inflammation in asthma, there has been an effort to incorporate inflammatory markers into its management. Measurement of fractional exhaled nitric oxide (FeNO) is a noninvasive marker of airway inflammation; however, the use of the available FeNO analyzer is limited by several factors including its cost and lack of transportability. The aim of this stud...
متن کاملDecreased Exhaled Nitric Oxide Levels in Patients with Mitochondrial Disorders
BACKGROUND Nitric oxide (NO) deficiency may occur in mitochondrial disorders (MD) and can contribute to the pathogenesis of the disease. It is difficult and invasive to measure systemic nitric oxide. NO is formed in the lungs and can be detected in expired air. Currently, hand-held fractional exhaled nitric oxide (FeNO) measurement devices are available enabling a fast in-office analysis of thi...
متن کاملATS workshop proceedings: exhaled nitric oxide and nitric oxide oxidative metabolism in exhaled breath condensate.
The field of noninvasive assessment of airway inflammation has developed rapidly since the discoveries in the late 1980s that nitric oxide (NO) is a central biological mediator and, in 1991, that exhaled breath contained NO (1). Accompanying this was the realization that asthma is an inflammatory airway syndrome, best treated by antiinflammatory agents. Subsequently, exhaled NO was found to be ...
متن کاملExhaled nitric oxide monitoring in COPD using a portable analyzer.
BACKGROUND The exhaled nitric oxide (FeNO) is a non-invasive marker of airway inflammation in asthma. A very recent statement has suggested FeNO as potential outcome in chronic obstructive pulmonary disease (COPD). Recently, a new hand-held FeNO analyzer (NIOX MINO) has been developed. PATIENTS AND METHODS We have evaluated the NIOX MINO in COPD patients and monitored FeNO levels during 1-yea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Respiratory medicine
دوره 104 9 شماره
صفحات -
تاریخ انتشار 2010