An optic disc grid: its evaluation in reproducibility studies on the cup/disc ratio.

نویسندگان

  • R A Hitchings
  • C Genio
  • S Anderton
  • P Clark
چکیده

A grid system is described which may be superimposed upon stereoscopic pairs of optic disc photographs. This grid system allowed reproducible inter- and intraobserver measurements of the cup/disc (C/D) ratio. The surface contour of the optic disc was not clear-cut in approximately 10% of the population studied, which led to a reduction in reproducibility of the measurement made within the group as a whole. As a result it was found that a large increase in the C/D ratio would have to occur for such change to be of statistical significance. Even with an optic grid as a reference system the serial measurements of the C/D ratio are unlikely to be of value in the management of patients with chronic glaucoma.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated volumetric evaluation of stereoscopic disc photography

PURPOSE To develop a fully automated algorithm (AP) to perform a volumetric measure of the optic disc using conventional stereoscopic optic nerve head (ONH) photographs, and to compare algorithm-produced parameters with manual photogrammetry (MP), scanning laser ophthalmoscope (SLO) and optical coherence tomography (OCT) measurements. METHODS One hundred twenty-two stereoscopic optic disc pho...

متن کامل

Ranking of optic disc variables for detection of glaucomatous optic nerve damage.

PURPOSE To describe optic disc variables assessed by evaluation of clinical optic disc photographs and to compare sensitivity and specificity of these optic disc parameters in identifying patients with ocular hypertension who have nerve fiber layer defects and normal visual fields and patients with visual field defects. METHODS The study included 500 normal subjects, 132 patients with ocular ...

متن کامل

An Efficacious Method of Cup to Disc Ratio Calculation for Glaucoma Diagnosis Using Super pixel

Glaucoma is a chronic eye disease that leads to vision loss. Since it cannot be cured, detecting the disease in time is important. The tests which are done to detect Glaucoma using intraocular pressure (IOP) are not sensitive enough for population based glaucoma screening. The assessment of Optic nerve head damage in retinal fundus images is both more promising and superior. In this paper the o...

متن کامل

The disc damage likelihood scale: reproducibility of a new method of estimating the amount of optic nerve damage caused by glaucoma.

PURPOSE The major objective of this study was to test the reproducibility of a new method of estimating the amount of optic disc damage in patients with glaucoma. METHODS The Disc Damage Likelihood Scale (DDLS) is based on the appearance of the neuroretinal rim of the optic disc corrected for disc diameter. The eight stages, extending from no damage to far advanced damage, are based on the wi...

متن کامل

Effect of optic disc size or age on evaluation of optic disc variables.

AIMS/BACKGROUND It has been reported that the number of optic nerve fibres decrease with age, and the cup/disc (C/D) ratio increases as the optic disc size increases. Consequently, the normal value of the optic disc variables measured by an optic disc analyser may change according to the optic disc size or age. The effect of individual variations in optic disc size or age on interpretation of o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 67 6  شماره 

صفحات  -

تاریخ انتشار 1983