Threshold-based insulin-pump interruption for reduction of hypoglycemia.

نویسندگان

  • Richard M Bergenstal
  • David C Klonoff
  • Satish K Garg
  • Bruce W Bode
  • Melissa Meredith
  • Robert H Slover
  • Andrew J Ahmann
  • John B Welsh
  • Scott W Lee
  • Francine R Kaufman
چکیده

BACKGROUND The threshold-suspend feature of sensor-augmented insulin pumps is designed to minimize the risk of hypoglycemia by interrupting insulin delivery at a preset sensor glucose value. We evaluated sensor-augmented insulin-pump therapy with and without the threshold-suspend feature in patients with nocturnal hypoglycemia. METHODS We randomly assigned patients with type 1 diabetes and documented nocturnal hypoglycemia to receive sensor-augmented insulin-pump therapy with or without the threshold-suspend feature for 3 months. The primary safety outcome was the change in the glycated hemoglobin level. The primary efficacy outcome was the area under the curve (AUC) for nocturnal hypoglycemic events. Two-hour threshold-suspend events were analyzed with respect to subsequent sensor glucose values. RESULTS A total of 247 patients were randomly assigned to receive sensor-augmented insulin-pump therapy with the threshold-suspend feature (threshold-suspend group, 121 patients) or standard sensor-augmented insulin-pump therapy (control group, 126 patients). The changes in glycated hemoglobin values were similar in the two groups. The mean AUC for nocturnal hypoglycemic events was 37.5% lower in the threshold-suspend group than in the control group (980 ± 1200 mg per deciliter [54.4 ± 66.6 mmol per liter] × minutes vs. 1568 ± 1995 mg per deciliter [87.0 ± 110.7 mmol per liter] × minutes, P<0.001). Nocturnal hypoglycemic events occurred 31.8% less frequently in the threshold-suspend group than in the control group (1.5 ± 1.0 vs. 2.2 ± 1.3 per patient-week, P<0.001). The percentages of nocturnal sensor glucose values of less than 50 mg per deciliter (2.8 mmol per liter), 50 to less than 60 mg per deciliter (3.3 mmol per liter), and 60 to less than 70 mg per deciliter (3.9 mmol per liter) were significantly reduced in the threshold-suspend group (P<0.001 for each range). After 1438 instances at night in which the pump was stopped for 2 hours, the mean sensor glucose value was 92.6 ± 40.7 mg per deciliter (5.1 ± 2.3 mmol per liter). Four patients (all in the control group) had a severe hypoglycemic event; no patients had diabetic ketoacidosis. CONCLUSIONS This study showed that over a 3-month period the use of sensor-augmented insulin-pump therapy with the threshold-suspend feature reduced nocturnal hypoglycemia, without increasing glycated hemoglobin values. (Funded by Medtronic MiniMed; ASPIRE ClinicalTrials.gov number, NCT01497938.).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The PILGRIM study: in silico modeling of a predictive low glucose management system and feasibility in youth with type 1 diabetes during exercise.

BACKGROUND Predictive low glucose management (PLGM) may help prevent hypoglycemia by stopping insulin pump delivery based on predicted sensor glucose values. MATERIALS AND METHODS Hypoglycemic challenges were simulated using the Food and Drug Administration-accepted glucose simulator with 100 virtual patients. PLGM was then tested with a system composed of a Paradigm(®) insulin pump (Medtroni...

متن کامل

“Let the Algorithm Do the Work”: Reduction of Hypoglycemia Using Sensor-Augmented Pump Therapy with Predictive Insulin Suspension (SmartGuard) in Pediatric Type 1 Diabetes Patients

BACKGROUND A sensor-augmented insulin pump (SAP) using the MiniMed® 640G system with SmartGuard™ technology allows an automatic stop of insulin delivery based on prediction of low glucose levels. Since pediatric patients are particularly prone to hypoglycemia, this device may offer additional protection beyond conventional sensor-augmented therapy. METHODS This prospective, pediatric multicen...

متن کامل

ASPIRE In-Home: rationale, design, and methods of a study to evaluate the safety and efficacy of automatic insulin suspension for nocturnal hypoglycemia.

Nocturnal hypoglycemia is a barrier to therapy intensification efforts in diabetes. The Paradigm® Veo™ system may mitigate nocturnal hypoglycemia by automatically suspending insulin when a prespecified sensor glucose threshold is reached. ASPIRE (Automation to Simulate Pancreatic Insulin REsponse) In-Home (NCT01497938) was a multicenter, randomized, parallel, adaptive study of subjects with typ...

متن کامل

کارآزمایی بالینی تنظیم قند خون بیماران دیابتی نوع 1 با استفاده از پمپ انسولین

Background: Pump therapy (CSII) is offered as a safe and effective treatment for patients with type 1 Diabetes. We examined the efficacy and safety of continuous subcutaneous Insulin Infusion Therapy for six months as a before-after clinical trial study among type 1 diabetic patients. This is the first survey of this experience in Iranian patients.Methods: We recruited, type 1 diabetic patients...

متن کامل

Designing a glycemic control strategy to maintain glucose homeostasis and prevent hypoglycemia for subjects with type 1 diabetes

This paper presents using the fractional PImDn controller module which manipulates insulin infusion rate to maintain normoglycemia in subjects with type 1 diabetes. To prevent severe hypoglycemia, a conventional proportional controller is used to regulate glucagon infusion rate when the blood glucose levels fall below a threshold. Two sets of controller parameters are obtained and evaluated. Fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The New England journal of medicine

دوره 369 3  شماره 

صفحات  -

تاریخ انتشار 2013