Truncation artifact reduction in spectroscopic imaging using a dual-density spiral k-space trajectory.
نویسندگان
چکیده
Truncation artifacts arise in magnetic resonance spectroscopic imaging (MRSI) of the human brain due to limited coverage of k-space necessitated by low SNR of metabolite signal and limited scanning time. In proton MRSI of the head, intense extra-cranial lipid signals "bleed" into brain regions, thereby contaminating signals of metabolites therein. This work presents a data acquisition strategy for reducing truncation artifact based on extended k-space coverage achieved with a dual-SNR strategy. Using the fact that the SNR in k-space increases monotonically with sampling density, dual-SNR is achieved in an efficient manner with a dual-density spiral k-space trajectory that permits a smooth transition from high density to low density. The technique is demonstrated to be effective in reducing "bleeding" of extra-cranial lipid signals while preserving the SNR of metabolites in the brain.
منابع مشابه
The truncation artifact in a skinny patient following myocardial perfusion SPECT
Myocardial perfusion SPECT is one of the most common imaging techniques performed in nuclear medicine departments. To avoid misleading interpretation, it is necessary to address the quality control and technical problems. The truncation artifact occurs when the patient size is large relative to the field of view of the camera, causing false perfusion defects in the LV myocardium, misinterpreted...
متن کاملMulti echo spiral imaging : Optimized k-space trajectories for T2* quantification
Introduction Effective and theoretical k-space trajectories differ due to eddy currents or gradient hardware imperfections. This is especially critical in fast imaging techniques using high gradient slew rates and amplitudes, with possibly complex k-space acquisition schemes (e.g. spiral, twisted projection). Although k-space trajectory calibration can be used to avoid distortions in reconstruc...
متن کاملImproved SNR/g using Small FOV Spatially Selective Pulses with Parallel Excitation
Introduction Recently, substantial effort in the area of transmit SENSE has focused on exciting uniform high flip angle profiles [1] and increasing the bandwidth of spatially selective excitations [2], with the aim of improving excitation homogeneity and making arbitrary shaped excitation for spectroscopic imaging feasible. Reduced FOV for cardiac imaging is an important application of spatiall...
متن کاملSelf-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging.
A fat-saturated twice-refocused spin echo sequence was implemented on a GE Signa 1.5-T whole-body system for diffusion-weighted imaging. Data were acquired using an analytically designed interleaved variable-density (VD) spiral readout trajectory. This flexible design algorithm allowed real-time prescription on the scanner. Each interleaf of the VD spiral oversampled the center of k-space. The ...
متن کاملParallel spectroscopic imaging reconstruction with arbitrary trajectories using k-space sparse matrices.
Parallel imaging reconstruction has been successfully applied to magnetic resonance spectroscopic imaging (MRSI) to reduce scan times. For undersampled k-space data on a Cartesian grid, the reconstruction can be achieved in image domain using a sensitivity encoding (SENSE) algorithm for each spectral data point. Alternative methods for reconstruction with undersampled Cartesian k-space data are...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance imaging
دوره 20 10 شماره
صفحات -
تاریخ انتشار 2002