Inversion in the steady state: contrast optimization and reduced imaging time with fast three-dimensional inversion-recovery-prepared GRE pulse sequences.
نویسندگان
چکیده
PURPOSE To evaluate the differences in contrast between 1-second delay and zero delay (for magnetization recovery) before the preparation radio-frequency pulse in three-dimensional, inversion-recovery (IR) fast gradient-echo (GRE) acquisitions. MATERIALS AND METHODS Mathematical simulations and measurements of brain image contrast were performed with healthy volunteers and 10 patients. RESULTS The zero-delay sequence generated T1-weighted contrast similar to that obtained with 1-second delay but was accompanied by a substantial reduction in imaging time. However, the zero delay prohibits full recovery of the longitudinal magnetization. Hence, the signal null characteristic of IR experiments is not easily observed, since it occurs (as a function of tissue T1) at very short inversion times (< 150 msec). CONCLUSION T1-weighted contrast comparable with that of magnetization-prepared rapid GRE sequences with a 1-second delay and preparation time (TP) of 600-700 msec can be achieved in less time by using a zero delay and a shorter TP (400-500 msec).
منابع مشابه
The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence
Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...
متن کاملComparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage
Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...
متن کاملTime-Spatial Labeling Inversion Pulse: Safe, Simple and Effective Non-contrast MR Angiography
5. Shimada K, Isoda H, Okada T, et al. Noncontrast-enhanced hepatic MR angiography with true steady-state free-precession and time spatial labeling inversion pulse: optimization of the technique and preliminary results. Eur J Radiol. 2009;70(1):111-117. 6. Shimada K, Isoda H, Okada T, et al. Non-contrast-enhanced MR portography with time-spatial labeling inversion pulses: comparison of imaging ...
متن کاملNeuro MR: principles.
The principles of contrast mechanisms and fast pulse sequences underlying neurological and neuroradiological application of MRI are introduced in this part of a two-part review. In particular, the relaxation time constants T(1), T(2), and T(2) (*) are introduced, along with pulse sequences harnessing their contrast, spin-echo, fast spin echo (FSE), inversion recovery (IR), gradient recalled ech...
متن کاملAn optimized 3D inversion recovery prepared fast spoiled gradient recalled sequence for carotid plaque hemorrhage imaging at 3.0 T.
An optimized 3D inversion recovery prepared fast spoiled gradient recalled sequence (IR FSPGR) on a 3-T scanner for carotid plaque imaging is described. It offers clear blood and fat signal suppression at the carotid artery bifurcation and highlights the regions of carotid plaque affected by hemorrhage at 3 T with high contrast and contrast-to-noise ratio compared with other sequences. It can p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 191 1 شماره
صفحات -
تاریخ انتشار 1994