Femur first surgical technique: a smart non-computer-based procedure to achieve the combined anteversion in primary total hip arthroplasty

نویسندگان

  • Mattia Loppini
  • Umile Giuseppe Longo
  • Emanuele Caldarella
  • Antonello Della Rocca
  • Vincenzo Denaro
  • Guido Grappiolo
چکیده

BACKGROUND The relevance of prosthetic component orientation to prevent dislocation and impingement following total hip arthroplasty (THA) has been widely accepted. We investigated the use of a non-computer-based surgery to address the reciprocal orientation of the acetabular and femoral components. METHODS In the femur first technique, the cup is positioned relative to the stem. When the definitive antetorsion of femoral component is fixed, the cup is positioned in a compliant anteversion to the stem. Clinical and radiographic assessments were performed before and 3 months after THA. Radiographic assessment was performed in standing position with the EOS 2D/3D radiography system. 3D images were used to preoperative anterior pelvic plane (APP) angle, postoperative acetabular inclination (AI) and anteversion (AA), and postoperative stem antetorsion. Clinical assessment was performed with Harris Hip Score (HHS). RESULTS Forty patients (40 hips) underwent primary THA with an average age of 61 years (range, 36-84). Average HHS increased from 43 ± 5 (range, 37-52) preoperatively to 97 ± 6 (range, 86-100) at the last follow-up (P < 0.0001). Average combined anteversion value of cup with liner and stem was 38° ± 9° (range, 12°-55°). Average AI value of cup with liner was 39° ± 6° (range, 30°-55°) in the group with standard stem and 45° ± 7° (range, 39°-58°) in the group with varized stem (P = 0.007). Relationship analysis showed no correlation between the combined anteversion values of the cup with liner and stem with APP angle values (r = 0.26, P = 0.87). CONCLUSIONS Femur first technique allows the surgeon to achieve a combined anteversion ranging from 25° to 50° with a cup inclination ranging from 30° to 50°. The cup is positioned according to the functional plane of the patient regardless the preoperative pelvic tilt.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Combined Anteversion in the Combined Anteversion Technique with Image-free Navigated Total Hip Arthroplasty

In recent literatures dealing with optimization of prosthetic alignment in total hip arthroplasty (THA), the concept of combined anteversion (CA), which is the sum of acetabular anteversion (AV) and femoral antetorsion (AT), has been addressed. Widmer attempted to determine the optimal CA using a computer simulation study . He proposed the “new safe zone” for the CA value to achieve essential r...

متن کامل

What do we get from navigation in primary THA?

Navigation in primary total hip arthroplasty has a history of over 20 years. During this process, imageless computer navigation can be particularly helpful in optimally restoring the hip's biomechanics. This involves the accurate placement of the acetabular component with the determination of the anteversion and abduction, whereby the navigated femur-first technique also allows for a calculatio...

متن کامل

Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial

BACKGROUND Impingement can be a serious complication after total hip arthroplasty (THA), and is one of the major causes of postoperative pain, dislocation, aseptic loosening, and implant breakage. Minimally invasive THA and computer-navigated surgery were introduced several years ago. We have developed a novel, computer-assisted operation method for THA following the concept of "femur first"/"c...

متن کامل

Adjusting the combined anteversion to maximize range of motion in total hip arthroplasty: Acetabular side or femoral side, which adjustment is more effective?

INTRODUCTION: Cup and stem positioning correlates each other in total hip arthroplasty (THA), and it is believed that optimal combined anteversion (CA), which is a sum of cup and stem anteversion (AV) angle, is about 40° – 60°. However, there are few studies that have compared which adjustment is more effective, changing a cup or a femoral stem to optimizing CA and increasing ROM. In this study...

متن کامل

Native femoral anteversion should not be used as reference in cementless total hip arthroplasty with a straight, tapered stem: a retrospective clinical study

BACKROUND Improper femoral and acetabular component positioning can be associated with instability, impingement, component wear and finally patient dissatisfaction in total hip arthroplasty (THA). The concept of "femur first"/"combined anteversion", incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position of the stem relative to the cup intrao...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017