Estimates of total analytical error in consumer and hospital glucose meters contributed by hematocrit, maltose, and ascorbate.

نویسندگان

  • Martha E Lyon
  • Jeffrey A DuBois
  • Gordon H Fick
  • Andrew W Lyon
چکیده

BACKGROUND Patients and physicians expect accurate whole blood glucose monitoring even when patients are anemic, are undergoing peritoneal dialysis, or have slightly elevated ascorbate levels. The objective of this study was to estimate analytical error in two consumer and two hospital glucose meters contributed by variations in hematocrit, maltose, ascorbate, and imprecision. METHODS The influence of hematocrit (20-60%), maltose, and ascorbate were tested alone and in combination with each glucose meter and with a reference plasma glucose method at three concentrations of glucose. Precision was determined by consecutive analysis (n=20) at three levels of glucose. Multivariate regression analysis was used to estimate the bias associated with the interferences, alone and in combination. Total analytical error was estimated as |% bias|+1.96 (% imprecision). RESULTS Three meters demonstrated hematocrit bias that was dependent upon glucose concentration. Maltose had profound concentration-dependent positive bias on the consumer meters, and the extent of maltose bias was dependent on hematocrit. Ascorbate produced small but statistically significant biases on three meters. Coincident low hematocrit, presence of maltose, and presence of ascorbate increased the observed bias and was summarized by estimation of total analytical error. Among the four glucose meter devices assessed, estimates of total analytical error in glucose measurement ranged from 6 to 68% under the conditions tested. CONCLUSIONS The susceptibility of glucose meters to clinically significant analytical biases is highly device-dependent, and low hematocrit exacerbated the observed analytical error.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the impact of hematocrit and other interference on the accuracy of hospital-based glucose meters.

BACKGROUND Most glucose meter comparisons to date have focused on performance specifications likely to impact subcutaneous dosing of insulin. We evaluated four hospital-based glucose meter technologies for accuracy, precision, and analytical interferences likely to be encountered in critically ill patients, with the goal of identifying and discriminating glucose meter performance specifications...

متن کامل

ISO‐Based Assessment of Accuracy and Precision of Glucose Meters in Dogs

BACKGROUND Portable blood glucose meters (PBGMs) allow easy glucose measurements. As animal-specific PBGMs are not available everywhere, those for humans are widely used. OBJECTIVES To assess the accuracy and precision of 9 PBGMs in canine whole blood (WB) and plasma, based on the ISO 15197:2013. ANIMALS Fifty-nine client-owned dogs attending the Veterinary Teaching Hospital. METHODS Anal...

متن کامل

Analytical Performance and Quality Control of a Glucose Monitor System

  Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...

متن کامل

Separation Efficiency of Glucose and Maltose from Industrial Effluent by Granular Activated Carbon

This paper describes the performance of Granular Activated Carbon (GAC) to adsorb and separate glucose and maltose solutes from the industrial effluents by adsorption process. In this study, the capability of Granular Activated Carbon (GAC) to adsorb glucose and maltose were experimentally examined. Commercial GAC (mesh 12-20), supplied by Sigma Aldrich company in...

متن کامل

Analysis of an electrochemical blood glucose monitoring system with hematocrit compensation: improved accuracy by design.

The article entitled "Hematocrit Compensation in Electrochemical Blood Glucose Monitoring Systems" by Teodorczyk and colleagues in this issue of Journal of Diabetes Science and Technology demonstrates that the OneTouch(®) Verio™ glucose meter meets current regulatory expectations for glucose meter performance and is relatively free from interference by hematocrit. The lack of influence of hemat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 4 6  شماره 

صفحات  -

تاریخ انتشار 2010