Analysis of UV-excited fluorochromes by flow cytometry using near-ultraviolet laser diodes.
نویسنده
چکیده
INTRODUCTION Violet laser diodes have become common and reliable laser sources for benchtop flow cytometers. While these lasers are very useful for a variety of violet and some ultraviolet-excited fluorochromes (e.g., DAPI), they do not efficiently excite most UV-stimulated probes. In this study, the next generation of InGaN near-UV laser diodes (NUVLDs) emitting in the 370-375-nm range have been evaluated as laser sources for cuvette-based flow cytometers. METHODS Several NUVLDs, ranging in wavelength from 370 to 374 nm and in power level from 1.5 to 10 mW, were mounted on a BD Biosciences LSR II and evaluated for their ability to excite cells labeled with the UV DNA binding dye DAPI, several UV phenotyping fluorochromes (including Alexa Fluor 350, Marina Blue, and quantum dots), and the fluorescent calcium chelator indo-1. RESULTS NUVLDs at the 8-10-mW power range gave detection sensitivity levels comparable to more powerful solid-state and ion laser sources, using low-fluorescence microsphere beads as measurement standards. NUVLDs at all tested power levels allowed extremely high-resolution DAPI cell cycle analysis, and sources in the 8-10-mW power range excited Alexa Fluor 350, Marina Blue, and a variety of quantum dots at virtually the same signal-to-noise ratios as more powerful UV sources. CONCLUSIONS These evaluations indicate that near-UV laser diodes installed on a cuvette-based flow cytometer performed nearly as well as more powerful solid-state UV lasers on the same instrumentation, and comparably to more powerful ion lasers on a jet-in-air system, and. Despite their limited power, integration of these small and inexpensive lasers into benchtop flow cytometers should allow the use of flow cytometric applications requiring UV excitation on a wide variety of instruments.
منابع مشابه
Discrimination of the Hoechst side population in mouse bone marrow with violet and near-ultraviolet laser diodes.
BACKGROUND Discrimination of stem cells with flow cytometric analysis of Hoechst 33342 efflux by the ABCG2 transporter (termed the Hoechst side population, or SP technique) is a valuable methodology for identifying bone marrow progenitors enriched with stem cells. Unfortunately, it requires a ultraviolet (UV) laser source, usually necessitating an expensive and maintenance-intensive argon- or k...
متن کاملAnalysis of violet-excited fluorochromes by flow cytometry using a violet laser diode.
BACKGROUND Low power violet laser diodes (VLDs) have been evaluated as potential replacements for water-cooled argon-ion and krypton-ion ultraviolet and violet lasers for DNA content analysis using the Hoechst dyes and 4,6-diamidino-2-phenylindole (Shapiro HMN, Perlmutter NG: Cytometry 44:133-136, 2001). In this study, we used a VLD to excite a variety of violet-excited fluorescent molecules im...
متن کاملViolet laser diodes in flow cytometry: an update.
INTRODUCTION In previous studies we and others have demonstrated the usefulness of violet laser diodes (VLDs) as replacement laser sources for krypton-ion lasers on stream-in-air cytometers. Previously available VLDs had a maximum available power of less than 25 mW; this was sufficient for excitation of densely labeled cell surface antigens using fluorochromes such as Cascade Blue or Pacific Bl...
متن کاملDPSS yellow-green 561-nm lasers for improved fluorochrome detection by flow cytometry.
INTRODUCTION Blue-green 488-nm laser sources are widespread in flow cytometry but suffer some drawbacks for cell analysis, including their excitation of endogenous proteins (resulting in high cellular autofluorescence) and their less-than-optimal coincidence with the excitation maxima of commonly used fluorochromes, including the phycoerythrins (PE). Longer wavelength lasers such as green heliu...
متن کاملSolid state yellow and orange lasers for flow cytometry.
Diode and DPSS lasers emitting a variety of wavelengths are now commonly incorporated into flow cytometers, greatly increasing our capacity to excite a wide variety of fluorochromes. Until recently, however, virtually no practical technology existed for generating yellow or orange laser light for flow cytometry that was compatible with smaller instrumentation. In this study, we evaluate several...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cytometry. Part A : the journal of the International Society for Analytical Cytology
دوره 61 1 شماره
صفحات -
تاریخ انتشار 2004