Improved accuracy of quantitative assessment of left ventricular volume and ejection fraction by geometric models with steady-state free precession.

نویسندگان

  • Holger Thiele
  • Ingo Paetsch
  • Bernhard Schnackenburg
  • Axel Bornstedt
  • Olaf Grebe
  • Ernst Wellnhofer
  • Gerhard Schuler
  • Eckart Fleck
  • Eike Nagel
چکیده

The purpose of this study was to determine whether steady-state free precession (SSFP) could improve accuracy of geometric models for evaluation of left ventricular (LV) function in comparison to turbo gradient echo (TGrE) and thereby reduce the acquisition and post-processing times, which are commonly long by use of the Simpson's Rule. In 25 subjects, cine loops of the complete heart in short and horizontal long-axis planes were acquired using TGrE (TR/TE/flip = 5.0/1.9/25) compared with SSFP (TR/TE/flip = 3.2/1.2/60). LV volumes and EF were measured with various geometric models for TGrE and SSFP. With three-dimensional data, the LV volumes were higher and the resulting EF lower for SSFP in contrast to TGrE (51 +/- 15% vs. 57 +/- 15%, p < 0.001). With SSFP, various geometric models yielded good to excellent correlations for LV volumes and LVEF compared to volumetric data (r = 0.94-0.98, mean relative difference 7.0-11.4%). In contrast, correlations were low using biplane or single-plane ellipsoid models in TGrE (r = 0.71-0.75, mean relative difference 15.9-30.2%). A new combined geometric model, taking all three dimensions into account, yielded the highest accuracy for SSFP in comparison to volumetric data (r = 0.99, mean relative difference 4.7%). Geometric models for assessment of LV volumes and EF yield higher accuracy and reproducibility by use of the SSFP sequence than by standard TGrE. This may increase clinical utility of magnetic resonance by shorter acquisition and processing times.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effects of Contrast Agent on Quantitative Morphological LV Parameters at 3T

Introduction and Aim Cardiac MRI (CMRI) is a reproducible, non-invasive tool which provides a rapid and accurate cardiac assessment, free from geometric assumptions. CMRI is now the most accurate modality for imaging morphological parameters such as end diastolic volume (EDV), end systolic volume (ESV), stroke volume (SV) and ejection fraction (EF), with Steady State Free Precession CMRI curren...

متن کامل

Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold.

OBJECTIVE This study compares single breath-hold 3D cine steady-state free precession (SSFP) MRI using sensitivity encoding (SENSE) with standard 2D cine SSFP imaging in the quantitative evaluation of global left ventricular (LV) function. MATERIALS AND METHODS The LV function of 22 healthy volunteers and 15 patients was evaluated using a standard 2D SSFP sequence and a 3D SSFP sequence with ...

متن کامل

VENTRICULAR FUNCTION Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging

Purpose. The aim of this project was to establish a database of left and right ventricular and left atrial dimensions in healthy volunteers using steady-state free precession cardiac magnetic resonance imaging, the clinical technique of choice, across a wide age range. Methods. 108 healthy volunteers (63 male, 45 female) underwent cardiac magnetic resonance imaging using steady-state free prece...

متن کامل

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

Quantification of the relationship between two cardiac magnetic resonance techniques: fast gradient echo and steady-state free precession for determination of left atrial volumes

Background Steady-state free precession (SSFP) results in larger volumes and lower ejection fraction for the left ventricle compared to fast gradient echo (fGRE) imaging. Similar comparisons for the left atrium (LA) are not available and may be relevant for 3T imaging and historical comparison to prior imaging datasets. As opposed to LV imaging, volumes in the LA are more commonly derived using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 4 3  شماره 

صفحات  -

تاریخ انتشار 2002