An Aptamer-Based Biosensor for Colorimetric Detection of Escherichia coli O157:H7
نویسندگان
چکیده
BACKGROUND An aptamer based biosensor (aptasensor) was developed and evaluated for rapid colorimetric detection of Escherichia coli (E. coli) O157:H7. METHODOLOGY/PRINCIPAL FINDINGS The aptasensor was assembled by modifying the truncated lipopolysaccharides (LPS)-binding aptamer on the surface of nanoscale polydiacetylene (PDA) vesicle using peptide bonding between the carboxyl group of the vesicle and the amine group of the aptamer. Molecular recognition between E. coli O157:H7 and aptamer at the interface of the vesicle lead to blue-red transition of PDA which was readily visible to the naked eyes and could be quantified by colorimetric responses (CR). Confocal laser scanning microscope (CLSM) and transmission electron microscopy (TEM) was used to confirm the specific interactions between the truncated aptamer and E. coli O157:H7. The aptasensor could detect cellular concentrations in a range of 10(4)~ 10(8) colony-forming units (CFU)/ml within 2 hours and its specificity was 100% for detection of E. coli O157:H7. Compared with the standard culture method, the correspondent rate was 98.5% for the detection of E. coli O157:H7 on 203 clinical fecal specimens with our aptasensor. CONCLUSIONS The new aptasensor represents a significant advancement in detection capabilities based on the combination of nucleic acid aptamer with PDA vesicle, and offers a specific and convenient screening method for the detection of pathogenic bacteria. This technic could also be applied in areas from clinical analysis to biological terrorism defense, especially in low-resource settings.
منابع مشابه
Point-of-care detection of Escherichia coli O157:H7 in water using AuNPs-based aptasensor
Objective(s): Access to safe drinking and irrigation water has always been one of the major human concerns worldwide. Thus, rapid, sensitive, and inexpensive approaches for pathogenic bacteria detection, such as Escherichia coli O157:H7 (EHEC) that can induce important infectious diseases, are highly on demand. Materials and Methods: In ...
متن کاملMonitoring of Escherichia coli O157:H7 in food samples using lectin based surface plasmon resonance biosensor.
A novel surface plasmon resonance (SPR) biosensor using lectin as bioreceptor was developed for the rapid detection of Escherichia coli (E. coli) O157:H7. The selective interaction of lectins with carbohydrate components from bacterial cells surface was used as the recognition principle for the detection. Five types of lectins from Triticum vulgaris, Canavailia ensiformis, Ulex europaeus, Arach...
متن کاملColorimetric detection of Escherichia coli O157:H7 using functionalized Au@Pt nanoparticles as peroxidase mimetics.
The presence of Escherichia coli (E. coli) in food and drinking water is a chronic problem worldwide. Protecting food against bacterial contamination and rapid diagnosis of infection require simple and rapid assays for detection of bacterial pathogens, including E. coli O157:H7. Here we report a rapid and novel colorimetric method for detecting E. coli O157:H7. This colorimetric method is based...
متن کاملFiber-Optic Biosensor Employing Alexa-Fluor Conjugated Antibody for Detection of Escherichia coli O157:H7 from Ground Beef in Four Hours
Fiber optic biosensor has a great potential to meet the need for rapid, sensitive, and real-time microbial detection systems. We developed an antibody-based fiber-optic biosensor to rapidly detect low levels of Escherichia coli O157:H7 cells in ground beef. The principle of the sensor is a sandwich immunoassay using an antibody which is specific for E. coli O157:H7. A polyclonal antibody was fi...
متن کاملSignal-off impedimetric immunosensor for the detection of Escherichia coli O157:H7
A signal-off impedimetric immune-biosensor based on gold nanoparticle (AuNP)-mediated electron transfer (ET) across a self-assembled monolayer (SAM) was the developed for highly sensitive detection of Escherichia coli O157:H7 bacteria. The biosensor was fabricated by covalently grafting an anti-Escherichia coli O157:H7 antibody onto SAM-modified gold electrodes. Following bacterial capture, the...
متن کامل