Comparison of properties of slow pathway potential between successful and unsuccessful radiofrequency applications in patients who underwent catheter ablation for atrioventricular nodal reentrant tachycardia.

نویسندگان

  • H Hirao
  • Y Muraoka
  • T Yamagata
  • H Matsuura
  • G Kajiyama
چکیده

Findings concerning selective slow pathway radiofrequency ablation for atrioventricular nodal reentrant tachycardia (AVNRT) using the slow pathway potential (SPP) guided method are reported. The electrogram at the SPP recording site showed double potentials consisting of the atrial potential (A) and SPP. However, SPP is usually recorded widely in the right atrial posteroseptal region. To examine whether there was any characteristic marker in the electrogram at the SPP recording site specific to successful RF application, the properties of SPP and its anatomical locations in both successful (S) (38 sites) and unsuccessful (UN) (28 sites) application sites were analyzed in 38 patients who underwent SPP-guided ablation. The distance between the upper margin of the coronary sinus ostium (UCSO) and the ablation catheter (ABL) (DUCSO-ABL) was shorter in S than in UN (2.3 +/- 6.3 mm vs. 9.0 +/- 5.2 mm below the level of UCSO, p < 0.001). The interval between A and SPP (A-SPP) was longer in S than in UN (44.2 +/- 9.9 msec vs. 24.0 +/- 7.0 msec, p < 0.001). RF applications at the more anterior sites with longer A-SPP were more successful than at other sites. The sensitivity and specificity of A-SPP (more than 40 msec) were superior to those of DUCSO-ABL (within 5 mm) as the marker for the successful application (sensitivity; 73.7% v.s. 68.4%, specificity; 100% v.s. 82.1%, respectively). In conclusion, the sites with longer A-SPP might be specific for successful ablation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temperature-controlled slow pathway ablation for treatment of atrioventricular nodal reentrant tachycardia using a combined anatomical and electrogram guided strategy.

AIMS Anatomical and electrogram-guided techniques have been used separately for slow pathway ablation in atrioventricular nodal reentrant tachycardia. The aims of the present study were to analyse electrogram characteristics of target sites and biophysical parameters using a combined anatomical and electrogram-guided technique for temperature-controlled radiofrequency catheter ablation of the s...

متن کامل

Successful radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia in a patient with dextrocardia due to unilateral pulmonary agenesis: a case report

Radiofrequency catheter ablation of the slow pathway is considered to be the treatment of choice for patients with atrioventricular nodal reentrant tachycardia. We report a 34-year-old female with mirror image dextrocardia due to unilateral pulmonary agenesis who underwent successful slow pathway ablation for typical atrioventricular nodal reentrant tachycardia. Using contrast injection, cardia...

متن کامل

Radiofrequency catheter ablation of atypical atrioventricular nodal reentrant tachycardia.

INTRODUCTION Published reports of radiofrequency ablation of atypical atrioventricular nodal reentrant tachycardia (AVNRT) have been limited. We present our experience in 10 consecutive patients with atypical AVNRT who underwent radiofrequency ablation of the "slow" AV nodal pathway. METHODS AND RESULTS There were 9 females and 1 male; their mean age was 44 +/- 19 years (+/- SD). The mean AVN...

متن کامل

Absence of junctional rhythm during successful slow-pathway ablation in patients with atrioventricular nodal reentrant tachycardia.

BACKGROUND The presence of junctional rhythm has been considered to be a sensitive marker of successful slow-pathway ablation. However, in rare cases, junctional rhythm was absent despite multiple radiofrequency applications delivered over a large area in the Koch's triangle, and successful ablation was achieved in the absence of a junctional rhythm. METHODS AND RESULTS This study included 35...

متن کامل

Atrioventricular nodal reentrant tachycardia ablation with radiofrequency energy during ongoing tachycardia: is it feasible?

INTRODUCTION Radiofrequency (RF) ablation of the slow pathway for treatment of atrioventricular nodal reentrant tachycardia (AVNRT) is conventionally performed during sinus rhythm. AIM To evaluate the clinical and electrophysiological features and the short- and long-term results of slow pathway RF ablation during ongoing AVNRT. MATERIAL AND METHODS A total of 282 consecutive patients with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hiroshima journal of medical sciences

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 2000