Contrast transfer and resolution limits for sub-angstrom high-resolution transmission electron microscopy.

نویسنده

  • Markus Lentzen
چکیده

The optimum imaging of an object structure at the sub-angstrom length scale requires precise adjustment of the lens aberrations of a high-resolution instrument up to the fifth order. A least-squares optimization of defocus aberration C1, third-order spherical aberration C3, and fifth-order spherical aberration C5 yields two sets of aberration coefficients for strong phase contrast up to the information limit: one for variable C1 and C3, at fixed C5, another for variable C1, C3, and C5. An additional correction to the defocus aberration, dependent on object thickness, is described, which becomes important for the use of image simulation programs in predicting optimum high-resolution contrast from thin objects at the sub-angstrom scale. For instruments with a sub-angstrom information limit the ultimate structure resolution, the power to resolve adjacent atom columns in a crystalline object, depends on both the instrumental pointspread and an object pointspread due to finite width of the atomic column potentials. A simulation study on a simple double-column model yields a range for structure resolutions, dependent on the atomic scattering power, from 0.070 nm down to 0.059 nm, for a hypothetical 300-kV instrument with an information limit of 0.050 nm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Linear versus non-linear structural information limit in high-resolution transmission electron microscopy.

A widely used performance criterion in high-resolution transmission electron microscopy (HRTEM) is the information limit. It corresponds to the inverse of the maximum spatial object frequency that is linearly transmitted with sufficient intensity from the exit plane of the object to the image plane and is limited due to partial temporal coherence. In practice, the information limit is often mea...

متن کامل

Atomic Scale Analysis of Complex Oxide Interfaces

Aberration correction in the Scanning Transmission Electron Microcope (STEM) is pushing the achievable spatial resolution for imaging and spectroscopy into the sub-angstrom regime, providing a new level of insight into the structure/property relations of complex materials. The combination of atomic-resolution Z-contrast scanning transmission electron microscopy and electron energy loss spectros...

متن کامل

Oral ATOMIC SCALE ANALYSIS OF COMPLEX OXIDE INTERFACES

Aberration correction in the Scanning Transmission Electron Microcope (STEM) is pushing the achievable spatial resolution for imaging and spectroscopy into the sub-angstrom regime, providing a new level of insight into the structure/property relations of complex materials. The combination of atomic-resolution Z-contrast scanning transmission electron microscopy and electron energy loss spectros...

متن کامل

Thin dielectric film thickness determination by advanced transmission electron microscopy.

High-resolution transmission electron microscopy (HR-TEM) has been used as the ultimate method of thickness measurement for thin films. The appearance of phase contrast interference patterns in HR-TEM images has long been confused as the appearance of a crystal lattice by nonspecialists. Relatively easy to interpret crystal lattice images are now directly observed with the introduction of annul...

متن کامل

Study of point spread in the aberration-corrected transmission electron microscopy.

High precision determination of atomic position is necessary for quantitative electron microscopy so that small width of peaks, which represent atoms in structural images, adequate resolution, and sufficiently strong image contrast are needed. The width of peak is usually determined by the point spread (PS) of instruments, but the PS of objects should also be taken into consideration in aberrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2008