Validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs

نویسندگان

  • Lindsey E. Bullen
  • Maria G. Evola
  • Emily H. Griffith
  • Gabriela S. Seiler
  • Korinn E. Saker
چکیده

OBJECTIVE The objective was to quantitatively evaluate the validity of ultrasonographic (US) muscle measurements as compared to the gold standard of computed tomography (CT) in the canine. DESIGN This was a prospective study. POPULATION Twenty-five, client-owned dogs scheduled for CT as part of a diagnostic work-up for the management of their primary disease process were included. MATERIALS AND METHODS Specific appendicular (cubital flexors and extensors, coxofemoral flexors and extensors) and axial (temporalis, supraspinatus, infraspinatus, lumbar epaxials) muscle groups were selected for quantitative measure based on CT planning and patient position. Prior to CT scan, the skin over the muscle sites was shaved and marked with a permanent marker. Patient body position was determined based on the patient's CT plan; positioning was consistent between CT and US imaging. To ensure identical imaging position for both CT and US measurements, radio-opaque fiducial markers were placed directly over the skin marks once the dog was positioned. Quantitative measurements (cm) for both lean muscle mass (LMM) and subcutaneous adipose (SQA) were recorded. Statistical comparisons between CT and US values were done separately for each site and type. RESULTS Muscle groups and associated SQA measured by US and CT were not statistically different based on an adjusted p-value using Bonferroni's correction (p < 0.0031). In addition, all LMM and SQA sites had good reliability and agreement (Cronbach's α = 0.8 - 1.0) between the two metrics, excluding the coxofemoral extensor muscle group (Cronbach's α = 0.73232). Linear regression analysis of muscle measures indicated close agreement (slope range 0.93-1.09) and minimal bias of variation (intercept range 0.05-0.11) between CT versus US modalities, with the exception of the coxofemoral extensor muscle. Similarly, SQA CT and US measures indicated close agreement with the slope range of 0.88-1.02 and minimal bias of variation with an intercept range of 0.021-0.098, excluding the cubital flexor and extensor groups. Additionally, the R2 values for these remaining LMM and SQA sites are reported as >0.897 for LLM and >0.8289 for SQA. CONCLUSIONS Ultrasound imaging of selected appendicular and axial muscle groups in dogs can provide comparable assessment of muscle thickness to the current gold standard, CT. In consideration of both statistical reliability to CT and cage-side accessibility, the temporalis, supraspinatus, infraspinatus, and lumbar epaxial LMM sites are considered the most useful targets for US LMM assessment in the canine. Our findings support the potential utility of US as a clinical tool in veterinary medicine to assess LMM status in patients. Additional studies are indicated to develop standardized protocols of its use in a cage-side setting and to elucidate the benefit of this modality, in conjunction with nutritional interventions, to manage body LLM stores in compromised patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Transcorneal and Transpalpebral Ultrasonographic Measurements of the Eye in Iranian Mix Breed Dog

Objective-The aim of this research was to compare transcorneal and transpalpebral ultrasonography study of the dimensions (ecobiometry) and the ultrasonographic aspect of Iranian mix breed dogs.Design- Experimental studyAnimals- . Ten adult male dogsProcedure- Ten adult male dogs with the mean age 4±1.39 years...

متن کامل

Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...

متن کامل

Evaluation the Accuracy of Lineartomography in Determining the Quantity of Maxillary Bone

Background & Aims: The accuracy of dental implants has increased in recent years. An accurate radiography from the region is needed for precise treatment planning in implants and for determining prognosis of treatment. Because this technique can demonstrate the buccolingual aspect, and due to its lower radiation dose, lower cost, and availability, in comparison with computed tomography, lineart...

متن کامل

Siemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

متن کامل

Comparison of supraspinatus sonographic thickness in empty can, full can and hug up testing positions in healthy women

Background: Rotator cuff injuries are the most common causes of shoulder pain and supraspinatus muscle is usually involved. Clinical tests are available and inexpensive tools for assessment of shoulder dysfunctions. The empty can (EC) and full can (FC) tests are considered as shoulder gold standard tests. Recently, hug up (HU) test has been developed to assess the supraspinatus. So far, no ultr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017