Innovative Methodology Noninvasive ultrasonic measurement of arterial wall motion in mice
نویسندگان
چکیده
Hartley, Craig J., Anilkumar K. Reddy, Sridhar Madala, Mark L. Entman, Lloyd H. Michael, and George E. Taffet. Noninvasive ultrasonic measurement of arterial wall motion in mice. Am J Physiol Heart Circ Physiol 287: H1426–H1432, 2004; 10.1152/ajpheart. 01185.2003.—Despite the extensive use of genetically altered mice to study cardiovascular physiology and pathology, it remains difficult to quantify arterial function noninvasively in vivo. We have developed a noninvasive Doppler method for quantifying vessel wall motion in anesthetized mice. A 20-MHz probe was held by an alligator clip and positioned over the carotid arteries of 16 mice, including six 3to 5-mo-old wild-type (WT), four 30-mo-old senescent (old), two apolipoprotein E null (ApoE), and four -smooth muscle actin null ( -SMA) mice. Doppler signals were obtained simultaneously from both vessel walls and from blood flow. The calculated displacement signals from the near and far walls were subtracted to generate a diameter signal from which the excursion and an augmentation index were calculated. The excursion ranged between 13 m (in ApoE) and 95 m (in -SMA). The augmentation index was lowest in the WT mice (0.06) and highest in the old mice (0.29). We conclude that Doppler signal processing may be used to measure vessel wall motion in mice with high spatial and temporal resolution and that diameter signals can replace pressure signals for calculating the augmentation index. This noninvasive method is able to identify and confirm characteristic changes in arterial properties previously associated with age, atherosclerosis, and the absence of vascular tone.
منابع مشابه
Kinematics parameter extraction of longitudinal movement of common carotid arterial wall in healthy and atherosclerotic subjects based on consecutive ultrasonic image processing
Introduction:In this study, a non-invasive method based on consecutive ultrasonic image processing is introduced to assess time rate changes of the carotid artery wall displacement, velocity and acceleration in the longitudinal direction. The application of these parameters to discriminate healthy and atherosclerotic arteries was evaluated. Methods:Longitudinal displacement rate of common ...
متن کاملExtraction of the Longitudinal Movement of the Carotid Artery Wall using Consecutive Ultrasonic Images: a Block Matching Algorithm
Introduction: In this study, a computer analysis method based on a block matching algorithm is presented to extract the longitudinal movement of the carotid artery wall using consecutive ultrasonic images. A window (block) is selected as the reference block in the first frame and the most similar block to the reference one is found in the subsequent frames. Material and Methods: The program was...
متن کاملA simple and novel method for acoustic streaming power measurement of ultrasonic horn
Ultrasonic horn with transfer of acoustic wave into an aqueous solution results in unique properties. When, transfer of sound wave into a liquid results in liquid movement in the direction of wave propagation which gradually loses its energy due to the viscous friction. This wave motion induces a flow which is known as acoustic streaming or micro-streaming. In this article, a simple innovative ...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کامل