Foot forces during exercise on the International Space Station.
نویسندگان
چکیده
Long-duration exposure to microgravity has been shown to have detrimental effects on the human musculoskeletal system. To date, exercise countermeasures have been the primary approach to maintain bone and muscle mass and they have not been successful. Up until 2008, the three exercise countermeasure devices available on the International Space Station (ISS) were the treadmill with vibration isolation and stabilization (TVIS), the cycle ergometer with vibration isolation and stabilization (CEVIS), and the interim resistance exercise device (iRED). This article examines the available envelope of mechanical loads to the lower extremity that these exercise devices can generate based on direct in-shoe force measurements performed on the ISS. Four male crewmembers who flew on long-duration ISS missions participated in this study. In-shoe forces were recorded during activities designed to elicit maximum loads from the various exercise devices. Data from typical exercise sessions on Earth and on-orbit were also available for comparison. Maximum on-orbit single-leg loads from TVIS were 1.77 body weight (BW) while running at 8mph. The largest single-leg forces during resistance exercise were 0.72 BW during single-leg heel raises and 0.68 BW during double-leg squats. Forces during CEVIS exercise were small, approaching only 0.19 BW at 210W and 95RPM. We conclude that the three exercise devices studied were not able to elicit loads comparable to exercise on Earth, with the exception of CEVIS at its maximal setting. The decrements were, on average, 77% for walking, 75% for running, and 65% for squats when each device was at its maximum setting. Future developments must include an improved harness to apply higher gravity replacement loads during locomotor exercise and the provision of greater resistance exercise capability. The present data set provides a benchmark that will enable future researchers to judge whether or not the new generation of exercise countermeasures recently added to the ISS will address the need for greater loading.
منابع مشابه
Computational Prediction of Muscle Moments During ARED Squat Exercise on the International Space Station.
Prevention of muscle atrophy caused by reduced mechanical loading in microgravity conditions remains a challenge for long-duration spaceflight. To combat leg muscle atrophy, astronauts on the International Space Station (ISS) often perform squat exercise using the Advanced Resistive Exercise Device (ARED). While the ARED is effective at building muscle strength and volume on Earth, NASA researc...
متن کاملCombining ergometer exercise and artificial gravity in a compact-radius centrifuge
Humans experience physiological deconditioning during space missions, primarily attributable to weightlessness. Some of these adverse consequences include bone loss, muscle atrophy, sensory-motor deconditioning, and cardiovascular alteration, which may lead to orthostatic intolerance when astronauts return to Earth. Artificial gravity could provide a comprehensive countermeasure capable of chal...
متن کاملAstronaut-induced disturbances to the microgravity environment of the Mir Space Station.
In preparation for the International Space Station, the Enhanced Dynamic Load Sensors Space Flight Experiment measured the forces and moments astronauts exerted on the Mir Space Station during their daily on-orbit activities to quantify the astronaut-induced disturbances to the microgravity environment during a long-duration space mission. An examination of video recordings of the astronauts mo...
متن کاملEffects of rehabilitation period with elastic training on frequency spectrum of foot forces in females with low back pain
Aims and background: The aim of this study was to investigate the effects of rehabilitation period with elastic training on frequency spectrum of foot forces in females with low back pain during walking. Materials and methods: The sample of this study included 20 girls with low back pain.The experimental group did elastic gait training for 6 weeks. Peak plantar forces during both pre and post...
متن کاملSquat exercise biomechanics during short-radius centrifugation.
INTRODUCTION Centrifuge-induced artificial gravity (AG) with exercise is a promising comprehensive countermeasure against the physiological de-conditioning that results from exposure to weightlessness. However, body movements onboard a rotating centrifuge are affected by both the gravity gradient and Coriolis accelerations. The effect of centrifugation on squat exercise biomechanics was investi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 43 15 شماره
صفحات -
تاریخ انتشار 2010