Extraneous lipid contamination in single-volume proton MR spectroscopy: phantom and human studies.
نویسندگان
چکیده
PURPOSE To determine the degree of extraneous lipid contamination in defined volumes of interest studied with single-volume proton MR spectroscopy. METHODS Single-volume proton MR spectroscopy was performed on a fat/water phantom and in three volunteers using the stimulated-echo acquisition mode (STEAM) and point-resolved spectroscopy (PRESS) localization methods. Three different volumes of interest (8, 27, and 64 cm3) were examined at echo times of 20, 135, and 270 for the STEAM sequences and 135 and 270 for the PRESS acquisitions in both the phantom and the volunteers (volumes of interest were placed adjacent to but not encompassing fat-containing structures, such as the scalp and retroorbital fat). The degree of lipid contamination was then correlated with measurements of the section profiles. RESULTS The PRESS method resulted in less extraneous lipid contamination in both phantom and volunteer studies. The STEAM method had the highest level of lipid contamination signal in phantom and human studies. In the volunteers, volumes of interest abutting fat-containing structures obtained with PRESS or STEAM sequences showed no lipid contamination. However, the STEAM sequences showed lipid signal in the volume of interest adjacent to orbital fat whereas the PRESS sequences did not. These observations are supported by the section profile studies, which showed that the actual volume excited by the STEAM sequence was 7% to 32% larger than that originally selected, while with PRESS the actual excited volume was 12% to 16% smaller than that originally selected. CONCLUSION In our MR unit, short-echo-time STEAM sequences (< or = 135 milliseconds) resulted in extraneous lipid contamination in phantom and human studies adjacent to the orbits. PRESS sequences showed no lipid contamination in volumes abutting fat structures in phantoms or humans. These results correlated closely with the configuration of the section profiles. Although these findings might be dependent on the MR unit used, our study could help determine extraneous lipid contamination for other MR units.
منابع مشابه
Effects of contrast material on single-volume proton MR spectroscopy.
BACKGROUND AND PURPOSE Administration of contrast material before proton MR spectroscopy may allow more accurate placement of the volume of interest, particularly in tumors; yet, some data have suggested that contrast material may alter the results of MR spectroscopy. To determine the validity of this contention, we performed pre- and postcontrast MR spectroscopy in patients with brain tumors a...
متن کاملChemical shift MR imaging methods for the quantification of transcatheter lipiodol delivery to the liver: preclinical feasibility studies in a rodent model.
PURPOSE To demonstrate the feasibility of using chemical shift magnetic resonance (MR) imaging fat-water separation methods for quantitative estimation of transcatheter lipiodol delivery to liver tissues. MATERIALS AND METHODS Studies were performed in accordance with institutional Animal Care and Use Committee guidelines. Proton nuclear MR spectroscopy was first performed to identify lipiodo...
متن کاملEffects of Defining Realistic Compositions of the Ocular Melanoma on Proton Therapy
Background: Recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. In spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. In the presented work, the effect of utilizing an eye model with ocular media on pr...
متن کاملIn vivo single-voxel proton MR spectroscopy in intracranial cystic masses.
PURPOSE Our objective was to evaluate the proton MR spectroscopic pattern of the cystic contents of various intracranial masses and to report characteristic spectral patterns that may be helpful in the differential diagnosis of these lesions. METHODS We evaluated 40 proton MR spectra obtained from cystic contents of various intracranial cystic masses in 39 patients, including gliomas (n = 14)...
متن کاملAutomatic placement of outer volume suppression slices in MR spectroscopic imaging of the human brain.
Spatial suppression of peripheral regions (outer volume suppression) is used in MR spectroscopic imaging to reduce contamination from strong lipid and water signals. The manual placement of outer volume suppression slices requires significant operator interaction, which is time consuming and introduces variability in volume coverage. Placing a large number of outer volume saturation bands for v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 18 7 شماره
صفحات -
تاریخ انتشار 1997