Assessment of personal direct-reading dust monitors for the measurement of airborne inhalable dust.

نویسنده

  • Andrew Thorpe
چکیده

The performances of five portable direct-reading dust monitors were investigated in a wind tunnel for a range of industrial dusts and three sizes of aluminium oxide test dust to mainly determine their suitability for measuring the inhalable fraction of airborne dust in workplaces. The instruments tested were Split 2 (SKC Ltd), Sidepak (TSI Inc.), Dataram (Thermo Electron Ltd), PDS-2 (Sibata Scientific Technology Ltd) and the Respicon TM (Hund Ltd). The instruments' responses were compared with reference dust samplers. These were the IOM sampler for the inhalable fraction and the Casella cyclone sampler for the respirable fraction. All instruments are predominantly responsive to and are designed to measure particles in the respirable size range, although two of the instruments, the Split 2 and Respicon TM, are claimed to be capable of measuring inhalable-sized particles. For the purpose of the tests, major modifications to an existing wind tunnel dust injection system were made to facilitate the generation of uniform concentrations of large inhalable-sized dust particles at low air velocities. Each monitor greatly underestimated the measurement of inhalable concentration for all the dusts tested, although the linearity was good over a wide range of concentrations for any particular size distribution of dust. However, their calibration factors, defined as the ratio of reference inhalable concentration to monitor concentration, were especially sensitive to changes in particle size as the response of the instruments decreased rapidly with increasing particle size. The monitors generally overestimated the measurement of respirable dust concentration by up to a factor of about 2, apart from the PDS-2, which underestimated it by a factor of up to 3. There was, however, a great deal more scatter in the reference respirable concentration measurements owing to the collection of small dust samples. Therefore, monitor linearity and effects of monitor response to changes in particle size could not be accurately investigated for the respirable fraction. The sampling head of the Split 2 monitor incorporates an IOM inlet and filter to gravimetrically collect the inhalable fraction of airborne dust. This can give a concurrent reference measure of inhalable airborne dust concentration. However, poor sealing within the sampling head resulted in some of the sampled dust not reaching the backup filter. This resulted in the Split 2 underestimating the reference inhalable dust concentration, which meant that it could not be accurately used as a calibration standard. Communications with the manufacturers have since revealed that the sampling head has recently been redesigned in order to improve the seal and eliminate leakage. The Respicon sampler gravimetrically underestimated the inhalable dust concentration, and did so increasingly as the particle size increased.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inhalable wood dust: Risk assessment of Occupational exposure

Background and Purpose: Wood dust have been approved as a harmful and carcinogenic agent for humans. This study aimed to evaluate risk assessment of Workers' exposure to inhalable wood dust among 100 workers in 25 furniture manufacturing workshops in one of the northern cities in Iran. Materials and Methods: NIOSH0501 method was used to assess the occupational exposure to Inhalable wood dust a...

متن کامل

Assessment of exposure to organic dust in a hemp processing plant.

The aim of this preliminary study was to assess exposure to various constituents of the organic dust generated during the processing of hemp in a small group of exposed workers. Airborne levels of inhalable dust, endotoxin and soluble protein, and the respirable, thoracic and inhalable fractions of fungal, bacterial and actinomycete contamination were measured in the personal breathing zone of ...

متن کامل

Occupational monitoring and health risks assessment of respiratory exposure to dust in an industrial unit of production Khak-e-Chini

Introduction: The respiratory system, as one of the most important organs of the human body, is affected by adverse health effects and consequences of particulate matter. this study was performed to purpose determine the occupational exposure of workers to crystalline silica of inhalable dust and determine its health risks. Method: In this analytical cross-sectional study, sampling was perform...

متن کامل

Application of porous foams for size-selective measurements of airborne wheat allergen.

BACKGROUND Exposure to airborne wheat allergen is a well-known cause of bakers' allergy and asthma. Airborne wheat allergen can be measured by enzyme immunoassays (EIAs) in extracts of inhalable dust samples, but only limited knowledge is available on the size distribution of wheat allergen-carrying particles. Recently, a new sampling medium, porous polyurethane foam, has been introduced for th...

متن کامل

Evaluating exposures to inhalable dust among dairy parlor workers

ii To: Mom and Dad iii All the really good ideas I'd ever had came to me while I was milking a cow. Dr. O'Shaughnessy for their valuable and constructive suggestions during the development of my thesis. I would also like to thank all the dairy farm workers who participated in and helped with this study. Finally, I would like to thank my parents, Ben, and Elissa for their ongoing support and enc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 51 1  شماره 

صفحات  -

تاریخ انتشار 2007