Letter to the editor regarding "Effect of low pass filtering on joint moments from inverse dynamics: implications for injury prevention".

نویسندگان

  • Timothy E Hewett
  • Gregory D Myer
  • Benjamin D Roewer
  • Kevin R Ford
چکیده

Analyses of joint moments are important in the study of human motion, and are crucial for our understanding of e.g. how and why ACL injuries occur. Such analyses may be affected by artifacts due to inconsistencies in the equations of motion when force and movement data are filtered with different cut-off frequencies. The purpose of this study was to quantify the effect of these artifacts, and compare joint moments calculated with the same or different cut-off frequency for the filtering of force and movement data. 123 elite handball players performed sidestep cutting while the movement was recorded by eight 240 Hz cameras and the ground reaction forces were recorded by a 960 Hz force plate. Knee and hip joint moments were calculated through inverse dynamics, with four different combinations of cut-off frequencies for signal filtering: movement 10 Hz, force 10 Hz, (10-10); movement 15 Hz, force 15 Hz; movement 10 Hz, force 50 Hz (10-50); movement 15 Hz, force 50 Hz. The results revealed significant differences, especially between conditions with different filtering of force and movement. Mean (SD) peak knee abduction moment for the 10-10 and 10-50 condition were 1.27 (0.53) and 1.64 (0.68) Nm/kg, respectively. Ranking of players based on knee abduction moments were affected by filtering condition. Out of 20 players with peak knee abduction moment higher than mean+1S D with the 10-50 condition, only 11 were still above mean+1 SD when the 10-10 condition was applied. Hip moments were very sensitive to filtering cut-off. Mean (SD) peak hip flexion moment was 3.64 (0.75) and 5.92 (1.80) under the 10-10 and 10-50 conditions, respectively. Based on these findings, force and movement data should be processed with the same filter. Conclusions from previous inverse dynamics studies, where this was not the case, should be treated with caution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between white tea and adipose tissue metabolism: The importance and necessity of future research regarding the effect of white tea on fat oxidation, compared to other Kinds of tea: Letter to the Editor

Obesity is a complex multifactorial disease. The worldwide prevalence of obesity has doubled since 1980 to an extent that nearly a third of the world’s population is now classified as overweight or obese. On the other hand, sports scientists have suggested exercise for the prevention of further spread of this disease. In addition to exercise, the use of natural fat-burning supplements, such as ...

متن کامل

Letter to the Editor: Application of Haddon Matrix in Disaster Management: A New Window in Disaster Mitigation Risk

In recent years, disaster management has been the focus of attention since disasters have been associated with huge destructions and consequences. Basically, disaster management techniques aim at the prevention and mitigation works as well as promotion of resilience. Haddon’s matrix was proposed as a conceptual model to understand the event and provide preventive measures in the field of injur...

متن کامل

Letter to Editor: Mortality Trends of Pilgrims in Hajj: An Implication for Establishment of Surveillance System

Hajj is one of the most important religious ceremonies of Muslims that is held in Saudi Arabia every year. However, trauma is the most important factor of mortality in this ceremony.

متن کامل

Stability Assessment of the Flexible System using Redundancy

In this study, dynamic behavior of a mooring line in a floating system is analyzed by probability approaches. In dynamics, most researches have shown the system model and environments by mathematical expression. We called this process as the forward dynamics. However, there is a limit to define the exact environments because of uncertainty. To consider uncertainty, we introduce the redundancy i...

متن کامل

An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo.

This paper examined if an electromyography (EMG) driven musculoskeletal model of the human knee could be used to predict knee moments, calculated using inverse dynamics, across a varied range of dynamic contractile conditions. Muscle-tendon lengths and moment arms of 13 muscles crossing the knee joint were determined from joint kinematics using a three-dimensional anatomical model of the lower ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 45 11  شماره 

صفحات  -

تاریخ انتشار 2012