Post-cam clunk syndrome after posterior stabilized total knee arthroplasty as a sign of early femoral component loosening

نویسندگان

  • Akihiko Toda
  • Katsumasa Tei
  • Tomoyuki Matsumoto
  • Kazunari Ishida
  • Hiroshi Sasaki
  • Kazuki Kodato
  • Yuichiro Nishizawa
  • Shinsuke Kirizuki
  • Nao Shibanuma
  • Hiroomi Tateishi
  • Ryosuke Kuroda
  • Masahiro Kurosaka
چکیده

Soft tissue impingements are well-known complications of total knee arthroplasty. The impingements usually occur between the medial or lateral femoral component and tibial insert, and between the patella and femoral components. We report a rare case of impingement of the soft tissue between the femoral intercondylar fossa and post of the polyethylene insert, which caused pain and walking disability. After the surgery for the arthroscopic removal of the soft tissue, the symptoms disappeared. However, prosthetic loosening of the femur occurred several months after the arthroscopic surgery, requiring revision surgery. We would propose to call this symptom as post-cam clunk syndrome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early results of posterior-stabilised NexGen Legacy total knee arthroplasty.

OBJECTIVE To retrospectively assess the early results of the NexGen Legacy posterior-stabilised total knee prosthesis, which is a newer version of the Insall-Burstein II posterior-stabilised implant. METHODS 48 consecutive elderly patients had 60 NexGen Legacy posterior-stabilised total knees. The mean follow-up duration was 21 months. Clinical evaluation was performed according to the Knee S...

متن کامل

Polyethylene Tibial Post Fracture in a Posterior Stabilized (Genesis II) Total Knee Arthroplasty

Posterior stabilizing knee prostheses have been increasing in popularity recently due to some studies showing excellent long-term survivorship, more consistent kinematics, technical ease, and higher range of motion.1,2 The posterior stabilized knee relies on a cam and post mechanism to replicate native femoral rollback. One of the major potential complications of this system is post fracture. T...

متن کامل

Post impingement in posterior stabilised total knee arthroplasty.

Posterior stabilised implants are a well-proven treatment for patients requiring primary total knee arthroplasty. Concerns about the posterior stabilised (PS) design have been raised and recent studies suggest that the post-cam articulation can be an additional source of polyethylene wear debris. In this study, the authors report impingement of the tibial post against the patellar component in ...

متن کامل

Gait Analysis of Conventional Total Knee Arthroplasty and Bicruciate Stabilized Total Knee Arthroplasty Using a Triaxial Accelerometer

One component of conventional total knee arthroplasty is removal of the anterior cruciate ligament, and the knee after total knee arthroplasty has been said to be a knee with anterior cruciate ligament dysfunction. Bicruciate stabilized total knee arthroplasty is believed to reproduce anterior cruciate ligament function in the implant and provide anterior stability. Conventional total knee arth...

متن کامل

Recurrent hemarthrosis caused by loosening of the femoral component after unicompartmental knee arthroplasty: a case report

A case of recurrent hemarthrosis of the knee after a mobile-bearing unicompartmental knee arthroplasty (UKA; Oxford UKA) is described. A 58-year-old man met with a road traffic accident 10 months after UKA. He developed anteromedial pain and hemarthrosis of the knee joint 1 month after the accident, which required multiple aspirations. Physical examination showed no instability. Plain radiograp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2018