Optimal left ventricular endocardial pacing sites for cardiac resynchronization therapy in patients with ischemic cardiomyopathy.

نویسندگان

  • David D Spragg
  • Jun Dong
  • Barry J Fetics
  • Robert Helm
  • Joseph E Marine
  • Alan Cheng
  • Charles A Henrikson
  • David A Kass
  • Ronald D Berger
چکیده

OBJECTIVES We sought to investigate the impact of left ventricular (LV) pacing site on mechanical response to cardiac resynchronization therapy (CRT) in patients with ischemic cardiomyopathy (ICM). BACKGROUND CRT reduces morbidity and mortality in patients with dyssynchronous LV failure; however, variability in response, particularly in ICM patients, poses ongoing challenges. Endocardial biventricular (BiV) stimulation may provide more flexibility in LV site selection and yield more natural transmural activation patterns. Whether this applies to ICM and whether optimal LV endocardial pacing locations vary among ICM patients remain unknown. METHODS Peak rate of LV pressure increase (dP/dt(max)) was measured at baseline, during VDD pacing at the right ventricular apex, and during BiV pacing from the right ventricular apex and 51 +/- 14 different LV endocardial sites in patients with ICM (n = 11). Seven patients already had an epicardial LV lead (CRT) in place, allowing comparison of epicardial BiV stimulation with that using an endocardial site directly transmural to the CRT-coronary sinus lead tip. Electroanatomic 3-dimensional maps with color-coded dP/dt(max) response defined optimal pacing regions delivering >or=85% of maximal increase in dP/dt(max). RESULTS Endocardial BiV pacing improved dP/dt(max) over right ventricular apex pacing in all patients (mean increase 241 +/- 38 mm Hg/s; p < 0.0001). In patients with pre-existing CRT leads, LV endocardial versus epicardial pacing at transmural sites yielded equivalent dP/dt(max) values. However, dP/dt(max) at the best endocardial site exceeded that achieved with the pre-implanted CRT device (mean increase 111 +/- 25 mm Hg/s; p = 0.004). An average of approximately 2 optimal endocardial sites were identified for each patient, located at the extreme basal lateral wall (8 of 11 patients) and other regions (9 of 11). Standard mid-LV free wall pacing yielded suboptimal LV function in 73% of patients. Optimal pacing sites were typically located in LV territories remote (9.3 +/- 3.6 cm) from the infarct zone. CONCLUSIONS CRT delivered at best LV endocardial sites is more effective than via pre-implanted coronary sinus lead pacing. The location of optimal LV endocardial pacing varies among patients with ICM, and individual tailoring may improve CRT efficacy in such patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left ventricular endocardial or triventricular pacing to optimize cardiac resynchronization therapy in a chronic canine model of ischemic heart failure.

Cardiac resynchronization therapy (CRT) is a proven treatment for heart failure but ~30% of patients appear to not benefit from the therapy. Left ventricular (LV) endocardial and multisite epicardial [triventricular (TriV)] pacing have been proposed as alternatives to traditional LV transvenous epicardial pacing, but no study has directly compared the hemodynamic effects of these approaches. Le...

متن کامل

Circulation: Cardiovascular Imaging Topic Review Circulation: Cardiovascular Imaging Editors’ Picks

The absence of clinical response in 30% to 40% of patients receiving cardiac resynchronization therapy (CRT) poses a great challenge to heart failure clinicians and device implanters. It is well documented that positioning of the left ventricular (LV) lead in areas of myocardial scar in patients with ischemic cardiomyopathy is associated with a diminished response to CRT. Regions of slow conduc...

متن کامل

Circulation: Cardiovascular Imaging Topic Review Circulation: Cardiovascular Imaging Editors’ Picks

The absence of clinical response in 30% to 40% of patients receiving cardiac resynchronization therapy (CRT) poses a great challenge to heart failure clinicians and device implanters. It is well documented that positioning of the left ventricular (LV) lead in areas of myocardial scar in patients with ischemic cardiomyopathy is associated with a diminished response to CRT. Regions of slow conduc...

متن کامل

Optimized Left Ventricular Endocardial Stimulation Is Superior to Optimized Epicardial Stimulation in Ischemic Patients With Poor Response to Cardiac Resynchronization Therapy

OBJECTIVES The purpose of this study was to identify the optimal pacing site for the left ventricular (LV) lead in ischemic patients with poor response to cardiac resynchronization therapy (CRT). BACKGROUND LV endocardial pacing may offer benefit over conventional CRT in ischemic patients. METHODS We performed cardiac magnetic resonance, invasive electroanatomic mapping (EAM), and measured the ...

متن کامل

A Simultaneous X-MRI and Non Contact Mapping Study of the Acute Hemodynamic Effect of Left Ventricular Endocardial and Epicardial Cardiac Resynchronization Therapy in Humans Running Title: Ginks et al:Mechanistic Insights Using Endocardial Pacing In Humans

Background Cardiac resynchronization therapy (CRT) utilising endocardial left ventricular (LV) pacing may be superior to conventional CRT. We studied the acute hemodynamic response to conventional CRT and LV pacing from different endocardial sites using a combined cardiac MRI and LV non-contact mapping protocol to gain insights into the underlying mechanisms. Methods and Results Fifteen patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 56 10  شماره 

صفحات  -

تاریخ انتشار 2010