Wind turbine model validation: Fusion of simulation and measurement data

نویسنده

  • Alexander Stotsky
چکیده

A new turbine model validation technique that is based on adaptation of look-up tables is described this paper. Simulation results from the VIDYN turbine simulation program and measurements from Big Glenn wind turbine, located outside Gothenburg, Sweden are used as an input to this new model validation technique. The models of the flapwise bending moment and power coefficient are validated for Big Glenn turbine. Measurement data are acquired during normal turbine operation. Verification results show good agreement between model outputs and measured data. The method allows prediction in a wide range of turbine operating variables, using only few measured points.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANFIS modeling and validation of a variable speed wind turbine based on actual data

In this research paper, ANFIS modeling and validation of Vestas 660 kW wind turbine based on actual data obtained from Eoun-Ebn-Ali wind farm in Tabriz, Iran, and FAST is performed. The turbine modeling is performed by deriving the non-linear dynamic equations of different subsystems. Then, the model parameters are identified to match the actual response. ANFIS is an artificial intelligent tech...

متن کامل

Modeling and Neuro-fuzzy Controller Design of a Wind Turbine in Full-load Region Based on Operational Data

In this paper, dynamic modeling of a Vestas 660 kW wind turbine and its validation are performed based on operational data extracted from Eoun-Ebn-Ali wind farm in Tabriz, Iran. The operational data show that the turbine under study, with a classical PI controller, encounters high fluctuations when controlling the output power at its rated value. The turbine modeling is performed by deriving th...

متن کامل

Implementation and Validation of IEC Generic Type 1A Wind Turbine Generator Model

This paper presents the implementation of the IEC generic Type 1A wind turbine generator (WTG) model in PowerFactory (PF) and the validation of the implemented model against field measurements. The IEC generic Type 1A WTG model structure is briefly described. The details are explained regarding how the two mass mechanical model is implemented when the generator mass is included in the PF built-...

متن کامل

On the development of a sliding mode observer-based fault diagnosis scheme for a wind turbine benchmark model

This paper addresses the design of an observer-based fault diagnosis scheme, which is applied to some of the sensors and actuators of a wind turbine benchmark model. The methodology is based on a modified sliding mode observer (SMO) that allows accurate reconstruction of multiple sensor or actuator faults occurring simultaneously. The faults are reconstructed using the equivalent output err...

متن کامل

On the development of a sliding mode observer-based fault diagnosis scheme for a wind turbine benchmark model

This paper addresses the design of an observer-based fault diagnosis scheme, which is applied to some of the sensors and actuators of a wind turbine benchmark model. The methodology is based on a modified sliding mode observer (SMO) that allows accurate reconstruction of multiple sensor or actuator faults occurring simultaneously. The faults are reconstructed using the equivalent output err...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • J. Systems & Control Engineering

دوره 228  شماره 

صفحات  -

تاریخ انتشار 2014