Amiba: Broadband Heterodyne Cmb Interferometry

نویسندگان

  • MING-TANG CHEN
  • HIROAKI NISHIOKA
  • KEIICHI UMETSU
  • FU-CHENG WANG
  • PROTY WU
چکیده

The Y. T. Lee Array for Microwave Background (AMiBA) has reported the first science results on the detection of galaxy clusters via the Sunyaev Zel’dovich effect. The science objectives required small reflectors in order to sample large scale structures (20’) while interferometry provided modest resolutions (2’). With these constraints, we designed for the best sensitivity by utilizing the maximum possible continuum bandwidth matched to the atmospheric window at 86 − 102 GHz, with dual polarizations. A novel wide-band analog correlator was designed that is easily expandable for more interferometer elements. MMIC technology was used throughout as much as possible in order to miniaturize the components and to enhance mass production. These designs will find application in other upcoming astronomy projects. AMiBA is now in operations since 2006, and we are in the process to expand the array from 7 to 13 elements. Subject headings: interferometry; millimeter-wave heterodyne receiver; interferometer; instrumentation; lagcorrelator; cosmology

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of Cosmic Microwave Background Polarization Fields for AMiBA Experiment

We have made a topological study of cosmic microwave background (CMB) polarization maps by simulating the AMiBA experiment results. A ΛCDM CMB sky is adopted to make mock interferometric observations designed for the AMiBA experiment. CMB polarization fields are reconstructed from the AMiBA mock visibility data using the maximum entropy method. We have also considered effects of Galactic foregr...

متن کامل

Observing the CMB with the AMiBA

I discuss the capabilities and limitations of the AMiBA for imaging CMB anisotropies. Michael Kesteven (ATNF-CSIRO) has proposed drift-scanning as an observing strategy for measuring and rejecting any instrumental response that the close-packed interferometers may have to the local environment. The advantages of mosaic imaging CMB anisotropies using a co-mounted interferometric array in a drift...

متن کامل

A Comparison of Electronic Heterodyne Moire Deflectometry and Electroni,; Heterodyne Holographic Interferometry for Flow Measurements

Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase object p . Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the intE-ferometric fringe shift. The phase objec...

متن کامل

Observational Strategies of CMB Temperature and Polarization Interferometry Experiments

We have simulated the interferometric observation of the Cosmic Microwave Background (CMB) temperature and polarization fluctuations. We have constructed data pipelines from the time-ordered raw visibility samples to the CMB power spectra which utilize the methods of data compression, maximum likelihood analysis, and optimal subspace filtering. They are customized for three observational strate...

متن کامل

Two-wavelength double heterodyne interferometry using a matched grating technique.

Two-wavelength double heterodyne interferometry is applied for topographic measurements on optically rough target surfaces. A two-wavelength He-Ne laser and a matched grating technique are used to improve system stability and to simplify heterodyne frequency generation.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009