Precision increase with two orthogonal analyzers in polarization-resolved second-harmonic generation microscopy.

نویسندگان

  • Philippe Réfrégier
  • Muriel Roche
  • Julien Duboisset
  • Sophie Brasselet
چکیده

We analyze the increase in precision of parameters estimation for polarization-resolved second-harmonic generation imaging microscopy when two intensities are measured with two orthogonal analyzers. The analysis is performed for measuring anisotropy parameters and molecule orientation for samples with cylindrical symmetry in the presence of photon noise with Poisson statistics. The improvement in comparison to global intensity measurement (i.e., without analyzer) is discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope

Three-dimensional second-harmonic fields, sample orientation, and susceptibility ratios of biological samples are measured using polarization-resolved second-harmonic generation (SHG) microscopy. The three-dimensional (3D) polarization is gathered by measurement of a series of holograms for which excitation and analyzer polarizations are systematically varied, and the 3D SHG field is recovered ...

متن کامل

Polarization-resolved second harmonic generation microscopy with a four-channel Stokes-polarimeter.

We developed a four-channel photon counting based Stokes-polarimeter for spatial characterization of polarization effects in second harmonic generation (SHG). We have implemented a calibration technique allowing quantitative measurement of polarization parameters, such as the degree of polarization (DOP), degree of linear polarization (DOLP), degree of circular polarization (DOCP), as well as a...

متن کامل

Investigating starch gelatinization through Stokes vector resolved second harmonic generation microscopy

The changes of the morphology during heating and the degree of crystallinity of dry and hydrated starch granules are investigated using second harmonic generation (SHG) based Stokes polarimetry. A spatial distribution of various polarization parameters, such as the degree of polarization (DOP), the degree of linear polarization (DOLP), and the degree of circular polarization (DOCP) are extracte...

متن کامل

Polarization-resolved second-harmonic-generation optical coherence tomography in collagen.

We describe a novel imaging technique, second-harmonic-generation optical coherence tomography (SHOCT). This technique combines the spatial resolution and depth penetration of optical coherence tomography (OCT) with the molecular sensitivity of second-harmonic-generation spectroscopy. As a consequence of the coherent detection required for OCT, polarization-resolved images arise naturally. We d...

متن کامل

2 Theoretical Background of Polarization-resolved Shg Microscopy 25

We thoroughly analyze the linear propagation effects that affect polarization-resolved Second Harmonic Generation imaging of thick anisotropic tissues such as collagenous tissues. We develop a theoretical model that fully accounts for birefringence and diattenuation along the excitation propagation, and polarization scrambling upon scattering of the harmonic signal. We obtain an excellent agree...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 37 20  شماره 

صفحات  -

تاریخ انتشار 2012