Solid-State Heating Synthesis of Poly (3,4-Ethylenedioxythiophene)/Gold/Graphene Composite and Its Application for Amperometric Determination of Nitrite and Iodate
نویسندگان
چکیده
A ternary composite of poly (3,4-ethylenedioxythiophene)/gold/graphene (PEDOT/Au/GO) for promising electrochemical sensor was synthesized by solid-state heating method. The interaction between the PEDOT, Au, and GO explored for detection of nitrite and iodate. It was found that the PEDOT/Au/GO composite had shale-like morphology with a uniform distribution of gold nanoparticles. Electrochemical experiments showed that the PEDOT/Au/GO composite modified electrode exhibited good electrocatalytic activity toward determination of iodate. The amperometric experiments at the PEDOT/Au/GO/GCE revealed that a good linear relationship existed between peak current and the concentration in the range of 100-1000 μM with the detection of 0.53 and 0.62 μM (S/N = 3) for nitrite and iodate, respectively. Moreover, the current response of PEDOT/Au/GO/GCE for nitrite and iodate at 10 μM was up to 9.59 and 11.47 μA, respectively. Mechanisms of the direct electron transfer between ion(nitrite or iodate)and the PEDOT/Au/GO composite.
منابع مشابه
Design and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticals
Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. This composite electrode exhibited 4-fold higher oxidation of INH, in accordance with peak densities, than the bare gold electrode. It was used the central compo...
متن کاملDesign and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticals
Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. This composite electrode exhibited 4-fold higher oxidation of INH, in accordance with peak densities, than the bare gold electrode. It was used the central compo...
متن کاملOne-pot synthesis of poly (3,4-ethylenedioxythiophene)-Pt nanoparticle composite and its application to electrochemical H2O2 sensor
Poly(3,4-ethylenedioxythiophene)-Pt nanoparticle composite was synthesized in one-pot fashion using a photo-assisted chemical method, and its electrocatalytic properties toward hydrogen peroxide (H2O2) was investigated. Under UV irradiation, the rates of the oxidative polymerization of EDOT monomer along with the reduction of Pt4+ ions were accelerated. In addition, the morphology of PtNPs was ...
متن کاملAmperometric Determination of Ascorbic Acid on an Au Electrode Modified by a Composite Film of Poly(3,4-ethylenedioxythiophene) and Superconductive Carbon Black.
A new composite film-modified electrode was prepared by the electropolymerisation of poly(3,4-ethylenedioxythiophene) (PEDOT) and superconductive carbon black (SCB) on a gold electrode. The PEDOT-SCB/Au electrode exhibited excellent ability towards the electrocatalytic oxidation of ascorbic acid, in terms of a 480 mV shift of the oxidation potential in the negative direction, and a dramatically...
متن کاملFabrication of a polymer/mediator composite modified electrode and its application to electrochemical detection of iodate
A polymer/mediator composite modified glassy carbon electrode (GCE) is fabricated for electrochemical detection of iodate (IO3 ). Flavin adenine dinucleotide (FAD) is chosen as mediator for sensing iodate, and 3,4 ethylenedioxythiophene (EDOT) is chosen for entrapping FAD and forming a conducting polymeric matrix, poly(3,4 ethylenedioxythiophene) (PEDOT). The PEDOT/FAD modification layer is ele...
متن کامل