Multicenter trial of the PowerLink bifurcated system for endovascular aortic aneurysm repair.

نویسنده

  • Jeffrey P Carpenter
چکیده

PURPOSE The purpose of this study was to assess the results of abdominal aortic aneurysm repair with the PowerLink bifurcated endovascular graft (Endologix, Inc, Irvine, Calif). METHOD Twelve centers used the PowerLink bifurcated system for elective endovascular aneurysm repair in 118 patients recruited during a 16-month interval and followed for a 25-month interval (mean follow-up, 16 months) as part of a pivotal US Food and Drug Administration trial. Stent grafts were oversized by 10% to 20% relative to computed tomographic scan-based diameter measurements. All repairs were performed in the operating room through one surgically exposed femoral artery and a contralateral 9F sheath percutaneously placed. Results were assessed with contrast-enhanced computed tomography and plain abdominal radiography at 1, 6, and 12 months after surgery. RESULTS Three failed insertions and one late conversion for endoleak remediation occurred, resulting in four conversions (3.3%) to open surgery. Of the failed insertions, two were from a faulty delivery system design, which was corrected. No failures occurred after the modification. One perioperative death (0.8%) occurred that was not device related. Eight late deaths were from unrelated causes, and one was from complications after reoperation for treatment of an endoleak. Endoleaks were noted in 19 patients (16%) at the time of the endograft procedure: 12 resolved spontaneously, four resolved with secondary interventions (three type I, one type II), and three underwent observation, yielding a 30-day endoleak rate of 5.9%. Two graft limb thromboses (0.8%) were seen. One graft migration (0.8%) was of no clinical significance. No ruptures or wire fractures were found. The mean aneurysm diameter was reduced from 51 mm (preoperative) to 45 mm (12 months; P <.0001). CONCLUSION The PowerLink system appears to be safe and effectively protects patients from abdominal aortic aneurysm rupture over the short to medium term. The low endoleak rate is superior to that reported for other devices. The graft and stent materials have thus far been free from failure and fatigue. The sutureless stent and endoskeleton design confer a number of unique advantages and challenges. Careful follow-up over the longer term is necessary to assure the durability of these results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess

Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...

متن کامل

Endovascular aortic aneurysm repair: association between anatomical fixation and outcomes using the Powerlink® device

Endovascular, catheter-based alternatives to open surgery for repair of abdominal aortic aneurysm have emerged over the last two decades using stent graft devices largely designed to mimic surgical grafts. These devices have similar characteristics, including relatively short main bodies, one long integrated limb, separate modular limb component(s) for assembly in situ, and requirement for fixa...

متن کامل

Frequency of Complications Following Endovascular Repair of Abdominal Aortic Aneurysm in Tehran Sina Hospital, 2011-2019

 Background and purpose: Abdominal aortic aneurysms (AAA) is a localized enlargement of infrarenal abdominal aorta. Endovascular aneurysm repair (EVAR) is a surgical method introduced for AAA repair. This study, for the first time in Iran, investigated the complications and mortality rate associated with EVAR.  Materials and methods: In this cross-sectional study, medical records were reviewed...

متن کامل

Billowing Of Endologix Powerlink Stent Mimicking Endoleaks.

INTRODUCTION Endoleaks remains one of the primary concerns of endovascular aortic aneurysm repair (EVAR) and is routinely followed with CT angiography (CTA). However, certain imaging findings can mimic endoleaks. CASE PRESENTATION A 65-year-old woman who had endovascular aortic repair (EVAR) of an abdominal aortic aneurysm with Endologix Powerlink system developed marked new circumferential c...

متن کامل

Repair of ruptured abdominal aortic aneurysms with bifurcated endografts: a single-center study

OBJECTIVE The aim of this study was to describe our early experience in the treatment of ruptured abdominal aortic aneurysms with bifurcated endografts. We report on our initial twelve-month experience using this approach. METHODS Clinical data on patients with ruptured abdominal aortic aneurysms treated at a single tertiary center in Brazil were prospectively recorded. The eligibility for en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular surgery

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 2002