Fat Suppression with Low SAR for SE EPI fMRI at 7T

نویسندگان

  • D. Ivanov
  • A. Schäfer
  • M. Streicher
  • R. Trampel
  • R. Turner
چکیده

Introduction: Functional imaging studies at 7 Tesla have given encouraging results, with increased CNR and stronger BOLD contrast [1]. However, a remaining problem at such field strengths is the increased specific absorption rate (SAR). A possible solution would be the omission or the modification of the RF pulses used in the imaging sequence. The SAR for gradient-echo EPI at 7 Tesla can be reduced significantly by omitting the fat suppression pulse, since at the optimal echo time for BOLD weighting (~25 ms) the signal from subcutaneous fat has already decayed [2]. T2* of the tissue region outside the scull at 7 Tesla is about 10 ms [2]. However, the T2 of fat is closer to 65 ms [3] so that for a spin-echo (SE) BOLD EPI acquisition, where the fat signal is refocussed, the fat saturation pulse cannot easily be omitted. Here we describe a simple method to remove the fat signal, by increasing the duration of the refocussing pulse to approximately the T2* value of fat, which has the additional virtue of reducing the SAR by a factor of 2.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Fat Suppression Methods for Functional and Diffusion Studies Using SE EPI at 7T

Introduction: MR imaging at ultra-high field strengths has given encouraging results for high resolution functional and diffusion-weighted brain image acquisition. For both applications, single-shot echo-planar imaging (EPI) is often used, because it acquires entire slices in a fraction of a second and thus avoids distributed artifacts associated with head motion. However, EPI acquisitions are ...

متن کامل

A Multi-Resolution Comparison of Single-Shot EPI, 3DFFE and PRESTO for fMRI at 7T

INTRODUCTION Single-shot Echo-Planar Imaging (EPI) is the sequence most commonly used for fMRI experiments. At high field, e.g. 7T, magnetic field inhomogeneities cause spins to become out of phase quickly, and distortion and signal dropout become severe [1]. Consequently, single-shot EPI fMRI suffers technical limitations at high field. Here we consider two alternatives to EPI for high field f...

متن کامل

Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging

Echo planar imaging (EPI) is an MRI technique of particular value to neuroscience, with its use for virtually all functional MRI (fMRI) and diffusion imaging of fiber connections in the human brain. EPI generates a single 2D image in a fraction of a second; however, it requires 2-3 seconds to acquire multi-slice whole brain coverage for fMRI and even longer for diffusion imaging. Here we report...

متن کامل

Evaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies

Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...

متن کامل

Comparison of the location and extent of BOLD activation in high spatial resolution SE and GE fMRI of the Motor Cortex at 7T

Introduction: fMRI studies generally employ gradient-echo (GE) BOLD contrast due to the limited signal change and signal-to-noise ratio (SNR) of spin echo (SE) BOLD contrast at standard field strength. Ultra-high field (7T) provides increased BOLD contrast-to-noise ratio (CNR) and decreases the contribution that large vessels make to GE BOLD contrast, due to higher capillary contribution and th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008