Bias Field Correction for MRI Images

نویسندگان

  • Jaber Juntu
  • Jan Sijbers
  • Dirk Van Dyck
  • Jan Gielen
چکیده

Bias field signal is a low-frequency and very smooth signal that corrupts MRI images specially those produced by old MRI (Magnetic Resonance Imaging) machines. Image processing algorithms such as segmentation, texture analysis or classification that use the graylevel values of image pixels will not produce satisfactory results. A pre-processing step is needed to correct for the bias field signal before submitting corrupted MRI images to such algorithms or the algorithms should be modified. In this report we discuss two approaches to deal with bias field corruption. The first approach can be used as a preprocessing step where the corrupted MRI image is restored by dividing it by an estimated bias field signal using a surface fitting approach. The second approach shows how to modify the fuzzy c-means algorithm so that it can be used to segment an MRI image corrupted by a bias field signal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

روشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)

The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...

متن کامل

Quantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation

Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...

متن کامل

Template-based bias correction: Application to paediatric brain MRI

INTRODUCTION Inhomogeneity of the magnetic field during the acquisition of MR images results in a smooth variation of intensities within the image referred to as bias field. This artefact complicates not only the further processing of the images, such as tissue segmentation or registration, but also affects visual assessment if the intensity variation becomes very pronounced. Modern MR scanners...

متن کامل

Noise Estimation, Noise Reduction and Intensity Inhomogeneity Correction in MRI Images of the Brain

Noise Estimation, Noise Reduction and Intensity Inhomogeneity Correction in MRI Images of the Brain Michael Eziashi Osadebey, Ph.D. Concordia University, 2015 Rician noise and intensity inhomogeneity are two common types of image degradation that manifest in the acquisition of magnetic resonance imaging (MRI) system images of the brain. Many noise reduction and intensity inhomogeneity correctio...

متن کامل

Efficient Bias Correction For MRI Image Denoising

Magnetic resonance imaging (MRI) is a popular radiology technique that is used for visualizing detailed internal structure of the body. Observed MRI images are generated by the inverse Fourier transformation from received frequency signals of a MR scanner system. Previous research has demonstrated that random noise involved in the observed MRI images can be described adequately by the so-called...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005