Comparison of blood flow models and acquisitions for quantitative myocardial perfusion estimation from dynamic CT.

نویسندگان

  • Michael Bindschadler
  • Dimple Modgil
  • Kelley R Branch
  • Patrick J La Riviere
  • Adam M Alessio
چکیده

Myocardial blood flow (MBF) can be estimated from dynamic contrast enhanced (DCE) cardiac CT acquisitions, leading to quantitative assessment of regional perfusion. The need for low radiation dose and the lack of consensus on MBF estimation methods motivates this study to refine the selection of acquisition protocols and models for CT-derived MBF. DCE cardiac CT acquisitions were simulated for a range of flow states (MBF = 0.5, 1, 2, 3 ml (min g)(-1), cardiac output = 3, 5, 8 L min(-1)). Patient kinetics were generated by a mathematical model of iodine exchange incorporating numerous physiological features including heterogenenous microvascular flow, permeability and capillary contrast gradients. CT acquisitions were simulated for multiple realizations of realistic x-ray flux levels. CT acquisitions that reduce radiation exposure were implemented by varying both temporal sampling (1, 2, and 3 s sampling intervals) and tube currents (140, 70, and 25 mAs). For all acquisitions, we compared three quantitative MBF estimation methods (two-compartment model, an axially-distributed model, and the adiabatic approximation to the tissue homogeneous model) and a qualitative slope-based method. In total, over 11 000 time attenuation curves were used to evaluate MBF estimation in multiple patient and imaging scenarios. After iodine-based beam hardening correction, the slope method consistently underestimated flow by on average 47.5% and the quantitative models provided estimates with less than 6.5% average bias and increasing variance with increasing dose reductions. The three quantitative models performed equally well, offering estimates with essentially identical root mean squared error (RMSE) for matched acquisitions. MBF estimates using the qualitative slope method were inferior in terms of bias and RMSE compared to the quantitative methods. MBF estimate error was equal at matched dose reductions for all quantitative methods and range of techniques evaluated. This suggests that there is no particular advantage between quantitative estimation methods nor to performing dose reduction via tube current reduction compared to temporal sampling reduction. These data are important for optimizing implementation of cardiac dynamic CT in clinical practice and in prospective CT MBF trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

Myocardial CT perfusion imaging in a large animal model: comparison of dynamic versus single-phase acquisitions.

OBJECTIVES This study sought to compare dynamic versus single-phase high-pitch computed tomography (CT) acquisitions for the assessment of myocardial perfusion in a porcine model with adjustable degrees of coronary stenosis. BACKGROUND The incremental value of the 2 different approaches to CT-based myocardial perfusion imaging remains unclear. METHODS Country pigs received stent implantatio...

متن کامل

Which quantitative perfusion estimation model is better at diagnosing myocardial ischaemia? A CE-MARC sub-study

Methods This was a retrospective sub-study using data from the CE-MARC trial (Greenwood et al., Lancet, 2012). A 50 patient sample of patients were selected such that the distribution of risk factors and disease status within the sample was representative of the full CE-MARC cohort. Quantitative myocardial blood flow (MBF) estimates were obtained from the MRI data using four previously proposed...

متن کامل

Comparison of plasma leptin levels in patients with normal, low and high risk myocardial perfusion scan [Persian]

Introduction: Leptin, secreted from adipose tissue may have some correlation with coronary artery disease according to some reports in literature. The mean concentration of plasma leptin in patients with normal and abnormal myocardial perfusion imaging (MPI) and relation of leptin levels, independently to abnormality in MPI after correction for body mass index (BMI) was evaluated. Methods...

متن کامل

Covid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT

A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 59 7  شماره 

صفحات  -

تاریخ انتشار 2014