Heidelberg Retina Tomograph und Papille

ثبت نشده
چکیده

PURPOSE: To compare the abilities of scanning laser polarimetry (SLP), optical coherence tomography (OCT), short-wavelength automated perimetry (SWAP), and frequency-doubling technology (FDT) perimetry to discriminate between healthy eyes and those with early glaucoma, classified based on standard automated perimetry (SAP) and optic disc appearance. To determine the agreement among instruments for classifying eyes as glaucomatous. METHODS: One eye of each of 94 subjects was included. Healthy eyes (n = 38) had both normal-appearing optic discs and normal SAP results. Glaucoma by SAP (n = 42) required a repeatable abnormal result (glaucoma hemifield test [GHT] or corrected pattern standard deviation [CPSD] outside normal limits). Glaucoma by disc appearance (n = 51) was based on masked stereoscopic photograph evaluation. Receiver operating characteristic (ROC) curve areas, sensitivities, and specificities were calculated for each instrument separately for each diagnosis. RESULTS: The largest area under the ROC curve was found for OCT inferior quadrant thickness (0.91 for diagnosis based on SAP, 0.89 for diagnosis based on disc appearance), followed by the FDT number of total deviation plot points of < or =5% (0.88 and 0.87, respectively), SLP linear discriminant function (0.79 and 0.81, respectively), and SWAP PSD (0.78 and 0.76, respectively). For diagnosis based on SAP, the ROC curve area was significantly larger for OCT than for SLP and SWAP. For diagnosis based on disc appearance, the ROC curve area was significantly larger for OCT than for SWAP. For both diagnostic criteria, at specificities of > or =90% and > or =70%, the most sensitive OCT parameter was more sensitive than the most sensitive SWAP and SLP parameters. For diagnosis based on SAP, the most sensitive FDT parameter was more sensitive than the most sensitive SLP parameter at specificities of > or =90% and > or =70% and was more sensitive than the most sensitive SWAP parameter at specificity of > or =70%. For diagnosis based on disc appearance at specificity of > or =90%, the most sensitive FDT parameter was more sensitive than the most sensitive SWAP and SLP parameters. At specificity > or = 90%, agreement among instruments for classifying eyes as glaucomatous was poor. CONCLUSIONS: In general, areas under the ROC curve were largest (although not always significantly so) for OCT parameters, followed by FDT, SLP, and SWAP, regardless of the definition of glaucoma used. The most sensitive OCT and FDT parameters tended to be more sensitive than the most sensitive SWAP and SLP parameters at the specificities investigated, regardless of diagnostic criteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimierte Segmentierung der Papille in HRT-Retinaaufnahmen

Kurzfassung. Der Papillenrand ist ein entscheidendes Merkmal zur Erkennung von krankhaften Veränderungen am Augenhintergrund. Zur Auswertung ist eine Segmentierung nötig, die meist manuell durch den Augenarzt vorgenommen werden muss. Eine robuste, automatische Segmentierung der Papille kann den Arzt unterstützen, die Reliabilität der Segmentierung erhöhen und eine Basis für eine automatische Di...

متن کامل

Factors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurements.

AIMS To evaluate the test-retest variability of stereometric parameter measurements made with the Heidelberg retina tomograph (HRT) and Heidelberg retina tomograph-II (HRT-II), and to establish which parameter(s) provided the most repeatable and reliable measurements with both devices. An investigation into the factors affecting the repeatability of the measurements of this parameter(s) was con...

متن کامل

Factors affecting the variability of the Heidelberg Retina Tomograph III measurements in newly diagnosed glaucoma patients.

PURPOSE To determine factors associated with the test-retest variability of optic nerve head (ONH) topography measurements with confocal scanning laser ophthalmoscopy (CSLO) in newly diagnosed glaucomatous patients. METHODS Consecutive patients with newly diagnosed primary open-angle glaucoma were prospectively enrolled. Patients presenting with any ocular disease other than glaucoma were exc...

متن کامل

Comparing mfERGs with estimates of cone density from in vivo imaging of the photoreceptor mosaic using a modified Heidelberg retina tomograph

The spatial variation in central retinal function determined from mfERG was compared to co-localised measurements of cone density in two normal subjects. Individual cone cells in the parafoveal region of the retina were identified from 1 degrees x1 degrees images of the photoreceptor mosaic using a modified Heidelberg retina tomograph (HRT). The variation in cone density compared well with prev...

متن کامل

A Bayesian framework for glaucoma progression detection using Heidelberg Retina Tomograph images

Glaucoma, the second leading cause of blindness in the United States, is an ocular disease characterized by structural changes of the optic nerve head (ONH) and changes in visual function. Therefore, early detection is of high importance to preserve remaining visual function. In this context, the Heidelberg Retina Tomograph (HRT), a confocal scanning laser tomograph, is widely used as a researc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001